LMZB-24 Outdoor Current Transformer

  • LMZB-24 Outdoor Current Transformer

Key attributes

Brand Wone Store
Model NO. LMZB-24 Outdoor Current Transformer
Rated voltage 22kV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LMZB

Product descriptions from the supplier

Description

Product Overview

LMZB-24 epoxy resin casting busbar type current transformer, is widely used outdoor for measuring current, electric energy and protective relaying in the electrical system with rated frequency 50Hz or 60Hz and highest voltage for equipment 24kV.  Rated primary current is 400-10000Aand rated secondary current is 5A or 1A.

Key Features

  • 24kV-Class Outdoor High-Voltage Adaptation Design:The LMZB1-24 outdoor current transformer features a 24kV rated voltage design with insulation levels reaching 75kV (lightning impulse) / 40kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, and is optimized specifically for scenarios such as 20kV and below outdoor substations, ring main units, and cable distribution boxes. Its structural design fully accounts for the long-term operational requirements of high-voltage outdoor environments, effectively resisting voltage fluctuations and insulation aging, reducing the risk of equipment failures caused by insulation breakdown, and ensuring the stable operation of the power system.

  •  All-Climate Protection Structure:This product adopts a dual protective barrier composed of silicone rubber composite insulation material and a corrosion-resistant aluminum alloy shell: it has passed 7000 hours of UV aging testing, enabling it to withstand long-term outdoor exposure; it reaches IP68 protection level, allowing continuous operation at 1 meter underwater. Meanwhile, through a specially designed structure, it can resist snowfall of 20mm/h and ice loads of 10mm thickness. Verified by 2000 hours of salt spray testing, it has a creepage distance of 20mm/kV, making it suitable for various harsh outdoor environments such as coastal areas, high-altitude regions, and cold areas, and reducing the impact of climatic factors on equipment performance.

  • Dual-Winding High-Precision Measurement System:It integrates a 0.2S-class metering winding and a 5P20-class protection winding. The metering winding maintains a ratio error of ≤±0.2% within the range of 1%~120% rated current, meeting the requirements of high-precision electric energy metering and line loss analysis; the protection winding has a composite error of ≤5% under 20 times the rated current, with a response time of ≤10ms, which can quickly trigger relay protection devices to ensure safe disconnection in case of power grid faults. It is equipped with 2 sets of ratio taps (such as 300/5A, 600/5A), which can be adjusted through an outdoor sealed changeover switch, adapting to different load currents without disassembly, thus improving the flexibility of on-site application.

  • Enhanced Safety and Environmental Adaptability:It is built with a pressure balance valve to avoid shell condensation and air pressure deformation caused by temperature differences, and can be optionally equipped with explosion-proof certification (Ex d IIB T4), making it suitable for outdoor areas with flammable and explosive risks. Its anti-electromagnetic interference performance complies with IEC 61000-4-5 standards, and it can resist 60kA lightning strikes (10/350μs waveform). It maintains stable measurement accuracy even in strong electromagnetic environments, providing reliable current monitoring and protection guarantees for 20kV-class outdoor power grids.

Main technical parameter

  • Rated voltage: 20 kV or 22kV etc

  • Rated secondary current:5Aor1A

  • Rated insulation level: 24/50/125 kV

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or IEC61869-1&2-2012 etc.

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.