low frequency on-line UPs power supply (single phase220V)

  • low frequency on-line UPs power supply (single phase220V)

Key attributes

Brand Switchgear parts
Model NO. low frequency on-line UPs power supply (single phase220V)
Rated frequency 50/60Hz
Output Voltage AC 220V/230V
Capacity 3kVA
Series HB

Product descriptions from the supplier

Description

Product Application
Suitable for industries such as finance, communication, insurance, transportation, taxation, military, securities, energy, education, government, and enterprises

SPWM pulse width modulation technology, lGBT power module and input and output isolation transformer are used to make UPsoutput a pure sine wave power source with low distortion, which is not disturbed by power grid fluctuation.Double transform technology and static electronic bypass technology are used to achieve zero switching time. With input and outputover voltage protection, input surge protection, phase sequence protection, battery over charge and over discharge protection,output overload short circuit protection, high temperature protection and other system protection and alarm functionsUltra wide input voltage, freguency range, reduce battery discharge chance, prolong battery life.Super cold start function, in the case of no power supply, can be full load cold start, to meet the emergency needs of usersJsina instantaneous control mode and effective value feedback control, high dynamic adiustment is realized and wavefommdistorion is reduced. uly meet the load jump from 0 to 100%, without switching to bypass, and ensure stable and reliable outputUltra wide input voltage, frequency range, reduce battery discharge chance, prolong battery life.

Humanized interface, barrier free human-machine communication
Intuitive LCD display content: UPS model, input/output voltage, frequency, load capacity, battery capacity, internal temperature, working status, working mode, and fault status.
The friendly human-machine interface design adopts Chinese LCD display, and the UPS operation status is clear at a glance, enabling zero distance communication between humans and machines.
Powerful compatibility
The wide input range and frequency range of mains power reduce the requirements of UPS for input mains power, and it is compatible with any form of power, including industrial power generation, wind power generation and other applications.
The output achieves precise zero phase synchronization with the power grid, meeting the high requirements of many devices for power supply and grid synchronization, which is conducive to the operation of rural power grids or small fuel generators when supplying power.
Intelligent communication tools for remote monitoring
RS232 and RS485 communication ports truly enable multi-purpose communication and remote monitoring. The optional dry contact interface uses passive contacts to effectively monitor the status of UPS. Through the DB9 dry node interface, the main abnormal information of UPS can be extracted through the dry node.
The optional SNMP card enables 100% remote monitoring and network management, making it easy to achieve intelligent monitoring of UPS, including close range point-to-point communication monitoring, medium range communication monitoring, and long-distance network monitoring. Real time monitoring of the operating status and parameters of UPS has been achieved; It has multiple functions such as automatic paging, sending email and voice, and remote power on/off of UPS.
Extremely environmentally friendly
Adopting green rectification and inverter technology to provide users with clean energy.
The whole machine adopts advanced anti electromagnetic interference technology, meets international standards, has good electromagnetic compatibility, and minimizes or even eliminates electromagnetic interference caused to the equipment to the greatest extent possible.

Technical parameters

Model

HB-1KS

HB-2KS

HB-3KS

HB-5KS

HB-6KS

HB-8KS

HB-10KS

HB-15KS

HB-20KS

HB-30KS

Input

 

 

 

 

 

 

 

 

 

 

Rated Capacity

1KVA

2KVA

3KVA

5KVA

6KVA

8KVA

10KVA

15KVA

20KVA

30KVA

Voltage Range

220VAC+25%380VAC±20%

Frequency Range

50 (60) HZ±5%

Phase Number

Single Phase + GND / Three Phase + N + GND

Output

 

Waveform

Pure Sine Wave

Voltage

220VAC

Frequency

50 (60) HZ

Voltage Stability

±1%

Frequency Stability

±0.5% (Battery Power Supply)

Waveform Distortion

Linear Load: < 3%; Non-linear Load < 5%

Battery

 

Battery Type

Lead-acid Maintenance-free Battery

DC Voltage

48V DC

48V DC

48V DC

192V DC

192V DC

192V DC

192V DC

192V DC

192V DC

192V DC

Number of Batteries

4 cells

4 cells

4 cells

16 cells

16 cells

16 cells

16 cells

16 cells

16 cells

16 cells

Float Voltage

55VDC

55VDC

55VDC

220VDC

220VDC

220VDC

220VDC

220VDC

220VDC

220VDC

System

 

 

 

 

 

 

 

 

 

 

Control Method

SPWM Pulse Width Modulation

Overload Capacity

Overload 125% for 1min; Overload 150% for 1S

Power Factor

0.8 Lagging

Conversion Time

0ms

Overall Efficiency

>85%

Human-machine Interface

 

LCD Display

Input/Output Voltage, Frequency, Battery Voltage, Load Power, Internal Temperature, Working Status, etc.

LED Indication

Mains, Inverter, Bypass, Battery, Overload, Abnormal, etc. Indications

RS232 Communication & Software Function

 

Software Function

1. Power Status Analysis 2. Timed Switching of UPS System 3. UPS Monitoring 4. Information Alarm and Sending to Mobile Phone 5. Automatic Archiving of Historical Records

Protection

 

Protection

Short Circuit Protection, Over-temperature, Overload, Low Battery Voltage, Output Over/Under Voltage, Surge, etc. Protection

Environment

 

Noise

< 60dB (1m from the Machine)

Operating Temperature

0 - 40℃

Humidity

20% - 90%, No Condensation

Altitude

<1500M

Mechanical Dimensions

 

Net Weight (KG, Without Battery)

37

53

65

56

61

100

110

200

245

300

Dimensions (WxDxH)(mm)

210*480*500

210*560*550

210*560*550

210*560*600

210*560*600

210*560*600

305*585*870

305*585*870

390*665*965

430*760 *980

FAQ
Q: What advantages does it have compared with high-frequency single phase 220V UPS?
A:

Compared with high-frequency UPS, it has obvious advantages: ① Higher reliability: Low-frequency transformer enhances overload capacity (125% overload for 10 minutes) and anti-interference, suitable for unstable mains areas; ② Longer service life: Low-frequency components generate less heat, service life up to 8-12 years; ③ Better load compatibility: Pure sine wave output, compatible with inductive loads (small motors, air conditioners) and precision devices; ④ Stronger stability: No voltage fluctuation during switching, protecting sensitive electronics.

Q: What is the core function and working principle of single phase 220V low frequency on-line UPS?
A:

Its core function is to provide uninterrupted, stable 220V power for single-phase loads, protecting devices from power outages, voltage fluctuations, surges and harmonic interference. Working principle: Adopt double conversion (AC-DC-AC) + low-frequency transformer design. When mains is normal, it converts 220V AC to DC to charge the battery, then converts DC to stable 220V pure sine wave AC for load supply; when mains fails, it switches to battery power with 0ms transfer time, avoiding data loss or device damage.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.