40.5kV 72.5kV 126kV 145kV Oil immersed current transformer

  • 40.5kV 72.5kV 126kV 145kV Oil immersed current transformer
  • 40.5kV 72.5kV 126kV 145kV Oil immersed current transformer

Key attributes

Brand Rockwell
Model NO. LVB Oil immersed current transformer
Rated voltage 40.5kV
Series LVB

Product descriptions from the supplier

Description

Product introduction:
The LVB series current transformers feature oil-impregnated paper insulation and an inverted structure, complying with IEC/IEEE standards. Installed in power lines, these series-connected transformers enable functions including energy measurement, metering, relay protection, and transient protection.

Product features:

  • Robust Primary Winding Design
    The through-type conductive rod structure ensures exceptional dynamic and thermal stability, with a maximum thermal stability current of 63kA/3s (in series configuration).

  • Ultra-Precise Measurement
    The primary winding passes through the center of the secondary winding, eliminating magnetic flux leakage and achieving measurement accuracies of 0.2S and 0.1.

  • Enhanced Secondary Protection
    Secondary windings are encapsulated in an aluminum-shielded housing with organic materials, safeguarding measurement and protection circuits from electrical breakdown.

  • Advanced Capacitor Screen Bushing
    Wound by a high-performance computer-controlled automatic wrapping machine using imported wide-width cable paper, the bushing ensures minimal process variation and excellent insulation. Partial discharge tests are conducted under power frequency voltage to guarantee reliability.

  • German-Made Vacuum Drying Technology
    Utilizing a LEYBOLD imported fully automatic vacuum drying system, the transformer undergoes variable-pressure vacuum drying and oil injection after assembly. Fully imported insulating materials ensure the overall dielectric loss factor (tanδ) remains below 0.3%.

  • Uniform Insulation Wrapping
    The head insulation is applied by an automatic binding machine, ensuring consistent, tight, and uniform wrapping for optimal performance.

  • Weatherproof Secondary Outlet Box
    The one-piece aluminum alloy casting features a dust-proof, waterproof, and breathable sealing structure for reliable outdoor operation.

  • Leakage-Proof Construction
    All component connections use argon arc welding, and the assembly is leak-tested with high-pressure nitrogen, eliminating oil leakage issues typical in oil-immersed products.

  • Corrosion-Resistant Materials
    The shell, base, and junction box are crafted from aluminum alloy, while the expander and nameplate use stainless steel—all exposed parts are rust-proof for lifelong durability.

  • Maintenance-Free Operation
    Designed for minimal upkeep, the transformer reduces long-term operational costs and downtime.

Technical parameter:
LVB Oil immersed current transformer-2.png
Oil immersed current transformer-3.png
Remark: Approximate dimensions and weights for special requirements, please consult us.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 60000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 60000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.