380V/400V/415V/480V/6.3kV/10.5kV MAN-Medium speed series generators

  • 380V/400V/415V/480V/6.3kV/10.5kV MAN-Medium speed series generators

Key attributes

Brand Wone
Model NO. MAN-Medium speed series generators
Voltage optional 380V
Rotate speed 1000r/min
Series MAN-Medium

Product descriptions from the supplier

Description

Description:

Diesel generator set type spectrum.The PWMAN series adopts MAN MAN engines and can be equipped with either CSSC Hyundai or Leroy somer AC generators.

Voltage optional:380V/400V/415V/480V/6.3kV/10.5kV(special voltage can be customized).

Technical parameters:

image.png

image.png

image.png

image.png

Remark:

  • All ratings are for reference only, please refer to the specific generator set technical data sheet for final power ratings.

  • All rating data are based on ISO 8528-1, 1SO 3046, DIN6271 operating under conditions using typical fan sizes and gear ratios. PAUWAY quotes a performance tolerance of ±5%.

  • Prime power = power under available load instead of the main grid. 10% overload is allowed for one hour of operation every 12 hours.

  • Standby power = power available under variable load in the event of a failure in the main grid, up to 500 hours per year. Overload is not allowed.

  • Rated power factor: 0.80.

  • N/A: Not available.

  • We reserves the right to change models, technical specifications, colors, configurations and accessories without prior notice. Please contact our sales team before ordering.

What are the performance characteristics of MAN-medium speed series generators?

High Reliability:

MAN Company boasts advanced manufacturing processes and stringent quality control systems, ensuring the reliability and stability of its generators. The engines are made from high-strength materials and utilize advanced manufacturing technologies, enabling them to withstand high-load operations and reduce the likelihood of faults. They are suitable for long-term continuous operation.

Higher Efficiency:

By optimizing the combustion process and improving intake efficiency, MAN's medium-speed generator series achieve high thermal efficiency. This allows for more effective conversion of fuel's chemical energy into electrical energy, thereby reducing fuel consumption and operational costs while enhancing energy utilization efficiency.

Lower Emissions:

Equipped with advanced combustion technologies and exhaust treatment devices, MAN's generators meet international environmental standards for emissions, minimizing pollution. Some models feature Selective Catalytic Reduction (SCR) systems, which effectively lower nitrogen oxide (NOx) emissions.

Low Noise and Vibration:

A series of noise reduction and vibration damping measures are implemented during design and manufacturing, such as optimizing engine structure, using soundproofing materials, and equipping with vibration-damping devices. This ensures that the generators produce minimal noise and vibration during operation, improving comfort and extending equipment lifespan.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.