Mining Transformer(distribution transformer)

  • Mining Transformer(distribution transformer)

Key attributes

Brand Vziman
Model NO. Mining Transformer
Rated capacity 1000kVA
Voltage grade 10KV
Series Mining Transformer

Product descriptions from the supplier

Description

Product overview:

 Mine general type transformer:

  • It is used in places where there is coal dust and biogas in mine and there is no explosion danger. It is used for electric driving and lighting.

  • Mine general transformer is strong in structure and low in appearance. The tank is mechanically strong enough to withstand pressures of 0.1 mpa without permanent deformation. The high and low voltage inlet and outlet lines of mine transformers are equipped with cable junction boxes filled with insulating adhesive.

  • Mine general transformer is equipped with no excitation voltage regulation, voltage regulation range is ±5%; The secondary coil leads to 6 terminals, which can use Y - connection or Delta - connection.

Mine flameproof transformer:

  • Used in places with explosive danger in mines. This kind of transformer is mostly made of dry type, the main structural characteristic is that all the joint surface of the box shell is made according to the flame-proof requirements, and it can bear the internal pressure of 0.8 mpa.

  • The capacity of mine dry-type transformer is usually 4000kVA (4MVA) and 2500kVA (2.5MVA), designed for electric drill, lighting, signal and other equipment power supply. Its inlet and outlet lines are led out by cable through the outlet sleeve.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Our products are mainly exported to Iran, Kazakhstan, Uzbekistan, Kazakhstan, Pakistan, Indonesia, Chile and other countries and regions.


Leading technology:

  •  Large capacity, low loss, low noise (< 65dB) more energy saving

  •  Excellent performance index, actual measurement is better than GB and IEC standards

  •  The product has strong over-load capacity and over-voltage capacity, and can run safely for a long time under rated load

  •  Strong impact resistance and short circuit resistance

  •  With microcomputer protection device (measurement, control, protection, communication, etc.)

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Use heat dissipation tubing (double row and three row tubing adopt insert mode) to achieve good heat dissipation effect.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  • Normal delivery period is 30 days.

  • Worldwide fast delivery.

What safety precautions need to be paid attention to when using mine transformers underground?


Explosion-proof Safety:

Shell Inspection:

  • For flameproof mining transformers, it is necessary to regularly inspect the integrity of the flameproof shell. The flameproof joint surfaces should remain smooth and free from damage, and the flameproof clearance must meet the specified standards. For example, the flameproof clearance is generally required to be within a specified range, such as around 0.1 - 0.2 mm. Any clearance exceeding the standard may lead to the failure of the explosion-proof performance.

  • The bolts and other connecting parts on the shell should be complete and tightened to prevent loosening during the operation due to vibration or other reasons, which may affect the flameproof effect.

Preventing Internal Faults from Causing Explosions:

It is essential to ensure that the quality and installation of the electrical components inside the transformer meet the requirements to prevent faults such as short circuits and overloads from generating electric sparks or high temperatures. For example, the insulation of the windings should be in good condition to avoid inter-turn short circuits. Meanwhile, appropriate overload protection and short-circuit protection devices should be installed so that when overload or short-circuit situations occur, the power supply can be cut off in a timely manner to prevent the generation of energy sufficient to cause explosions inside the transformer.

Electrical Safety:

Grounding Safety:

  • Mining transformers must have reliable grounding. The grounding resistance should meet the specified requirements, and generally, the grounding resistance is required to be no greater than 2Ω. Good grounding can lead the current into the earth when leakage or other faults occur in the transformer, thus avoiding electric shocks to personnel.

  • The grounding devices should be regularly inspected to ensure that the grounding connections are firm and that the grounding electrodes are free from corrosion and other damage. For example, if the grounding electrodes are in a damp underground environment for a long time, they are prone to rust and corrosion, which will reduce the grounding performance and need to be replaced in a timely manner.

Preventing Electric Shocks:

  • The high-voltage and low-voltage terminals of the transformer should be enclosed or protected to prevent accidental contact by personnel. During maintenance and other operations, the power supply must be cut off first, and a warning sign saying "Someone is working, Do not switch on" should be hung.

  • Underground operators should be equipped with personal protective equipment such as insulating gloves and insulating boots, and they should receive relevant electrical safety training to be familiar with the operation and safety precautions of the transformer.




Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    1. Challenges in High-Voltage Power Systems1.1 High-voltage power systems, as the core of power transmission, face critical challenges: Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements. Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages. Poor Environmental Adapt
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 Grid Frequency Fluctuations and Stability IssuesThe intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within mil
    05/13/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.