• Mining Transformer(distribution transformer)
Mining Transformer(distribution transformer)
discuss personally
Model
BK11-1000/10
Basic info
Brand Vziman
Model NO. Mining Transformer
Rated capacity 1000kVA
Voltage grade 10KV
Series Mining Transformer
Product Detail

Product overview:

 Mine general type transformer:

  • It is used in places where there is coal dust and biogas in mine and there is no explosion danger. It is used for electric driving and lighting.

  • Mine general transformer is strong in structure and low in appearance. The tank is mechanically strong enough to withstand pressures of 0.1 mpa without permanent deformation. The high and low voltage inlet and outlet lines of mine transformers are equipped with cable junction boxes filled with insulating adhesive.

  • Mine general transformer is equipped with no excitation voltage regulation, voltage regulation range is ±5%; The secondary coil leads to 6 terminals, which can use Y - connection or Delta - connection.

Mine flameproof transformer:

  • Used in places with explosive danger in mines. This kind of transformer is mostly made of dry type, the main structural characteristic is that all the joint surface of the box shell is made according to the flame-proof requirements, and it can bear the internal pressure of 0.8 mpa.

  • The capacity of mine dry-type transformer is usually 4000kVA (4MVA) and 2500kVA (2.5MVA), designed for electric drill, lighting, signal and other equipment power supply. Its inlet and outlet lines are led out by cable through the outlet sleeve.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Our products are mainly exported to Iran, Kazakhstan, Uzbekistan, Kazakhstan, Pakistan, Indonesia, Chile and other countries and regions.


Leading technology:

  •  Large capacity, low loss, low noise (< 65dB) more energy saving

  •  Excellent performance index, actual measurement is better than GB and IEC standards

  •  The product has strong over-load capacity and over-voltage capacity, and can run safely for a long time under rated load

  •  Strong impact resistance and short circuit resistance

  •  With microcomputer protection device (measurement, control, protection, communication, etc.)

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Use heat dissipation tubing (double row and three row tubing adopt insert mode) to achieve good heat dissipation effect.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  • Normal delivery period is 30 days.

  • Worldwide fast delivery.

What safety precautions need to be paid attention to when using mine transformers underground?


Explosion-proof Safety:

Shell Inspection:

  • For flameproof mining transformers, it is necessary to regularly inspect the integrity of the flameproof shell. The flameproof joint surfaces should remain smooth and free from damage, and the flameproof clearance must meet the specified standards. For example, the flameproof clearance is generally required to be within a specified range, such as around 0.1 - 0.2 mm. Any clearance exceeding the standard may lead to the failure of the explosion-proof performance.

  • The bolts and other connecting parts on the shell should be complete and tightened to prevent loosening during the operation due to vibration or other reasons, which may affect the flameproof effect.

Preventing Internal Faults from Causing Explosions:

It is essential to ensure that the quality and installation of the electrical components inside the transformer meet the requirements to prevent faults such as short circuits and overloads from generating electric sparks or high temperatures. For example, the insulation of the windings should be in good condition to avoid inter-turn short circuits. Meanwhile, appropriate overload protection and short-circuit protection devices should be installed so that when overload or short-circuit situations occur, the power supply can be cut off in a timely manner to prevent the generation of energy sufficient to cause explosions inside the transformer.

Electrical Safety:

Grounding Safety:

  • Mining transformers must have reliable grounding. The grounding resistance should meet the specified requirements, and generally, the grounding resistance is required to be no greater than 2Ω. Good grounding can lead the current into the earth when leakage or other faults occur in the transformer, thus avoiding electric shocks to personnel.

  • The grounding devices should be regularly inspected to ensure that the grounding connections are firm and that the grounding electrodes are free from corrosion and other damage. For example, if the grounding electrodes are in a damp underground environment for a long time, they are prone to rust and corrosion, which will reduce the grounding performance and need to be replaced in a timely manner.

Preventing Electric Shocks:

  • The high-voltage and low-voltage terminals of the transformer should be enclosed or protected to prevent accidental contact by personnel. During maintenance and other operations, the power supply must be cut off first, and a warning sign saying "Someone is working, Do not switch on" should be hung.

  • Underground operators should be equipped with personal protective equipment such as insulating gloves and insulating boots, and they should receive relevant electrical safety training to be familiar with the operation and safety precautions of the transformer.




Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry