• 380V/400V/415V/480V/6.3kV/10.5kV SME series diesel alternators
380V/400V/415V/480V/6.3kV/10.5kV SME series diesel alternators
discuss personally
Model
FD-1200D-1320
FD-1100D-1200
FD-1000D-1100
FD-800D-880
FD-600D-660
FD-550D-600
Basic info
Brand Wone
Model NO. PAUWAY-SME series alternators
Prime power 600KW
Reserve power 660KW
Series SME
Product Detail

Description:

Diesel generator set type spectrum.

The PWS Series - uses SME brand engines from a joint venture between China and Mitsubishi, with the option of Stamford, Marathon or Leroy-Somer alternators.

Voltage optional: 380V/400V/415V/480V/6.3kV/10.5kV (special voltage can be customized).

Technical parameters:

image.png

Remark:

  • All ratings are for reference only, please refer to the specific generator set technical data sheet for final power ratings.

  • All rating data are based on ISO 8528-1, 1SO 3046, DIN6271 operating under conditions using typical fan sizes and gear ratios. PAUWAY quotes a performance tolerance of ±5%.

  • Prime power = power under available load instead of the main grid. 10% overload is allowed for one hour of operation every 12 hours.

  • Standby power = power available under variable load in the event of a failure in the main grid, up to 500 hours per year. Overload is not allowed.

  • Rated power factor: 0.80.

  • N/A: Not available.

  • We reserves the right to change models, technical specifications, colors, configurations and accessories without prior notice. Please contact our sales team before ordering.


What is Fuel Injection Technology?

Working Principle:

Taking the electronic control gasoline injection system as an example, the electric fuel pump is installed inside the fuel tank. It draws fuel from the tank and pressurizes it. The pressurized fuel then passes through a fuel filter to remove impurities before being delivered to the distributor pipe located above the engine. The distributor pipe connects to injectors mounted on the intake manifold of each cylinder.

The injector is essentially an electromagnetic valve controlled by the computer (Electronic Control Unit, ECU). Based on signals from sensors such as the air flow sensor and crankshaft position sensor, the ECU calculates the engine's air intake volume and speed, determining the basic fuel injection quantity accordingly. It further adjusts the fuel injection quantity based on operating parameters like throttle opening, engine coolant temperature, and intake air temperature. The ECU controls the duration of each fuel injection cycle to regulate the amount of fuel injected, ensuring that the fuel is sprayed in a fine mist into the intake manifold where it mixes with air and is drawn into the cylinders during the intake stroke.

Advantages:

Improved Fuel Economy:

  • Precise Fuel Injection Control: By accurately controlling the fuel injection quantity, it ensures complete combustion of fuel, reducing waste and lowering fuel consumption.

Enhanced Power Performance:

  • Optimized Fuel Injection for Various Conditions: The system can promptly adjust the fuel injection quantity and timing according to different engine conditions (e.g., idle, acceleration, high-speed driving), optimizing the air-fuel mixture concentration. This improves the engine's output power and torque, enhancing acceleration performance.

Reduced Exhaust Emissions:

  • Complete Combustion: Precise fuel injection control promotes more thorough combustion, reducing emissions of harmful gases such as carbon monoxide, hydrocarbons, and nitrogen oxides, thus meeting increasingly stringent environmental standards.



Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!