• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


RWV-300 High Performance AC DRIVE

  • RWV-300 High Performance AC DRIVE

Key attributes

Brand RW Energy
Model NO. RWV-300 High Performance AC DRIVE
Output current 3.7A
Power capacity 3kVA
Input current 5A
Adapt motor 1.5kW
Series RWV

Product descriptions from the supplier

Description

Description :

A Variable Frequency Drive (VFD) is a power control device widely used in the field of industrial automation. It integrates functions such as motor control, energy-saving regulation, communication, and monitoring, enabling precise speed control and operational status management of AC motors.The VFD adopts a modular design concept, offering high flexibility and programmability, which significantly reduces maintenance workload and spare parts requirements while meeting diverse application needs. As an ideal alternative to traditional motor control methods, the VFD provides notable advantages in improving energy efficiency, optimizing control accuracy, and extending equipment lifespan.

Main function introduction:

  • Chinese and English LCD display, easy to install and debug;

  • The Japanese wide and large structure, the product margin is large,

  • Can be used in hot weather occasions;

  • With speed tracking function, can be a good application of fan secondary start;

  • Can do 220V, 380V, or 220/380 and other voltages;

  • With short circuit, grounding and other protection;

  • Can add master/slave control card, communication expansion card, PG card;

  • Asynchronous motor, synchronous motor optional;

 

Product model description

image.png

Technology parameters:

image.png

image.png

image.png

image.png

image.png

image.png

image.png

 

Wiring Schematic Diagram :

企业微信截图_17402046418189.png

What is a variable frequency drive?

A variable frequency drive is an electronic device that can convert alternating current (AC) of a fixed frequency into AC with adjustable frequency and voltage, thereby controlling the speed and torque of an electric motor. It mainly consists of a rectifier that converts AC into direct current (DC). After voltage stabilization in the DC link, an inverter then converts the DC back into AC with the required frequency and voltage. It is widely used in industries, heating, ventilation, and air - conditioning (HVAC) systems, the automotive sector, etc., to achieve motor speed regulation, energy conservation, and precise operation control.

 

FAQ
Q: Can I add an expansion card?
A:

Support adding master-slave control cards, communication expansion cards, and PG cards. Multi motor synchronization with master-slave card, and communication with PLC with communication card. Strong scalability, adaptable to different needs, flexible and practical.

Q: What scenarios are suitable for low power?
A:

Around 30kW, suitable for small equipment such as fans and pumps. 35A output current, 40kVA power, small size, easy installation. The first choice for upgrading small factories and equipment, with high cost-effectiveness and hassle free use.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.