SC Series Dry-Type Transformer

  • SC Series Dry-Type Transformer
  • SC Series Dry-Type Transformer
  • SC Series Dry-Type Transformer
  • SC Series Dry-Type Transformer
  • SC Series Dry-Type Transformer

Key attributes

Brand ROCKWILL
Model NO. SC Series Dry-Type Transformer
Rated capacity 800kVA
Primary voltage 35kV
Secondary voltage 0.4kV
Series SC Series

Product descriptions from the supplier

Description

Overview

Dry-type transformers are versatile medium-voltage power distribution transformers that are essential for applications where safety, environmental concerns, and reliability are paramount. They are commonly used in commercial, industrial, healthcare, and public infrastructure settings, and other special applications. Their ability to operate without liquid coolants makes them ideal for indoor and sensitive environments.

Safe & Eco-friendly: Fireproof, non-polluting, and safe for direct operation at the load center.

Compact Design: Easy to install and service, providing low-noise and long lasting operation.

Enhanced Performance: Advanced heat dissipation with forced air cooling enhancing operational capacity.

Superior Durability: Engineered for both indoor and outdoor applications; minimal maintenance needed due to rugged construction.

 

Operating condition

1.working temperature:-5℃~40℃

2.Relative humidity: <95% (25℃) 

3.In the ambient, there should not has the gas that corroding metal, destroying insulation. The transformer should not be corroded by water, rain or snow.

4.Altitude: <2000m

 

If you need to know about more parameters , Please check the model selection manual.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • ROCKWILL 12kV Indoor Vacuum Circuit Breaker (VSC Series) Technical Solution
    Ⅰ. Core Functions & Performance Electrical Parameters Parameter Value Notes Rated Voltage 12kV - Rated Current 630A, 800A, 1250A, 1600A Customizable Short-Circuit Breaking Capacity 20kA, 25kA, 31.5kA Customizable Power-Frequency Withstand Voltage (1min) Dry: 48kV / Wet: 38kV DL/T403 Compliant Lightning Impulse Withstand Voltage 75kV - Mechanical Life ≥10,000 operations Spring mechanism, oil-free design Short-
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.