• SC Series epoxy casting dry-type transformer
  • SC Series epoxy casting dry-type transformer
SC Series epoxy casting dry-type transformer
discuss personally
Model
SC(B)-10-630
SC(B)-10-500
SC(B)-10-400
SC(B)-10-315
SC(B)-10-250
SC(B)-10-200
SC(B)-10-160
SC(B)-10-125
SC(B)-10-100
SC(B)-10-80
SC(B)-10-50
SC(B)-10-30
Basic info
Brand POWERTECH
Model NO. SC Series epoxy casting dry-type transformer
Rated capacity 160kVA
Primary voltage 10.5kV
Secondary voltage 0.4kV
Series SC Series
Product Detail

Overview

1. Optimized winding design and epoxy resin casting process, with partial discharge level less than 3pC, leading the industry.
2. Flame-retardant, fire and explosion-proof, environmentally friendly, low loss, good energy-saving effect, economical operation, and maintenance-free.
3. Windings use enameled copper wire or copper foil, with epoxy resin casting process, providing good mechanical strength and strong overload capacity.
4. The transformer is easy to wire and can be equipped with voltmeters, ammeters, power indicators, circuit breakers, etc., according to user requirements. It can also use our company's developed intelligent module to comprehensively monitor the transformer's operating status, including real-time power transmission, operating voltage and current, operating temperature, insulation performance monitoring, etc.

 

Environmental Conditions for Used

Altitude: ≤ 2000m (products for altitudes above 2000m can be customized)
Ambient temperature: -40℃ ~+55℃
Relative humidity: ≤ 95%


Application:

Epoxy resin cast dry-type transformers are suitable for load centers and places with special fire prevention requirements. They can provide stable, reliable, and safe power supply to ensure normal equipment operation and personnel safety. They are widely used in power transmission and distribution systems, hotels, high-rise buildings, commercial centers, sports venues, petrochemical plants, subways, stations, airports, offshore drilling platforms, and other locations.

 

If you need to know about more parameters, Please check the model selection manual.↓↓↓

Or you are welcome to contact us.↓↓↓

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!