6kV 10kV Series air-core current-limiting reactor

  • 6kV 10kV Series air-core current-limiting reactor

Key attributes

Brand POWERTECH
Model NO. Series air-core current-limiting reactor
Rated voltage 10kV
Rated normal current 200A
Reactance 4%
Series XKGKL

Product descriptions from the supplier

Description

Description:

The current-limiting reactor is connected in series with the power system to limit the short-circuit current when the power system fails. When a short circuit occurs in the line, the current-limiting reactor uses its reactor characteristics to limit the short-circuit current of the line within a certain limit, so as to facilitate the smooth and effective removal of the fault of the switchgear. Current-limiting reactors generally use air-core reactors with good linearity of reactance values. The current-limiting reactor can operate safely and reliably at long-term rated current. In the case of failure, the ampere turns increase by several times or dozens of times, but its resistance value or the ability to limit the short-circuit current cannot be reduced, so the current-limiting reactor should be made into a hollow product rather than an iron-core product.

Feature:

  •  Multi-layer parallel air duct structure, epoxy glass fiber wrapping, uniform impact potential distribution, good ability to withstand short-circuit current.

  • Using computer-aided design, the structure and parameters of the product can be quickly and accurately determined according to the customer's requirements.

  •  The dry hollow form makes up for the disadvantages of oil leakage in the oil-immersed reactor, and there is no concern about core saturation, and the inductance value is linear.

  • The winding is wound with a variety of small cross-section film-wrapped wires, which has the characteristics of excellent insulation performance, low loss, light weight, small size, and maintenance-free.

  •  The entire outer surface of the reactor is coated with an anti-ultraviolet protective layer, which can be used indoors and outdoors, and the installation method is flexible, which can be stacked in three phases or arranged horizontally in three phases.

Technical indicators:

  • The parameters of rated voltage, rated current and supporting capacitors are shown in the technical parameter table.

  • Overload capacity: 1.35 times the rated current for continuous operation.

  • Thermal stability: It can withstand the rated current at the last of the rated reactance rate for 2s.

  • Dynamic stability performance: It can withstand 2.55 times of thermal stability current, time 0.5s, and no thermal mechanical damage.

  • Temperature rise: the average temperature rise of the coil is ≤ 75k (resistance method).

Parameters:

Insulation Level: LI60AC35, LI75AC42

企业微信截图_17331911257456.png

企业微信截图_17331915759690.png

企业微信截图_1733191282709.png

企业微信截图_17331917691924.png

企业微信截图_17331914508860.png

企业微信截图_17331915109334.png

What is the current limiting principle based on inductance of series air-core current limiting reactors?

Current Limiting Principle Based on Inductance:

  • According to Faraday's law of electromagnetic induction, when current flows through the windings of a reactor, it generates a magnetic field around the windings. This magnetic field, in turn, opposes the change in current, as described by Lenz's Law.

  • A series-connected air-core current-limiting reactor utilizes this principle. When a short-circuit fault or an excessive current occurs in the circuit, the inductance of the reactor impedes the rapid rise of the current, limiting its magnitude. This protects other equipment in the circuit from the impact of high currents.

  • For example, in a power transmission system, if a short circuit occurs on a line, the series-connected air-core current-limiting reactor will quickly increase the impedance of the circuit, preventing the short-circuit current from reaching excessively high values instantaneously. This provides additional time for protective devices, such as circuit breakers, to operate, ensuring the safety and stability of the system.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 580000m² Total staff: Highest Annual Export(usD): 120000000
Workplace: 580000m²
Total staff:
Highest Annual Export(usD): 120000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Core Value and Innovative Applications of 12kV Medium Voltage Switchgear in Smart Substations​
    With the Rapid Development of Smart Grids and the Integration of Renewable Energy Medium Voltage (MV) Switchgear, as the core power distribution equipment in substations, directly determines the stability of the power system through its reliability, intelligence, and space efficiency. This article delves into the key technologies, scenario-specific solutions, and practical benefits of Medium Voltage Switchgear in substations.Core Requirements for Substation ScenariosHigh Reliability Requirements
    06/12/2025
  • Withdrawable 12kV Medium Voltage Switchgear: The Indispensable Pivot of Flexibility and Safety in Smart Grids
    At the core of medium-voltage power distribution systems in industrial facilities, commercial complexes, and data centers, switchgear acts as a silent commander, governing the lifeline of electrical flow. Among various solutions, ​Withdrawable Switchgear​has become synonymous with reliability in modern MV systems due to its unique design philosophy. Compared to fixed switchgear, its "withdrawable" feature delivers compelling advantages, setting new benchmarks for ​operational efficiency​and ​per
    06/12/2025
  • Core Dilemma in Southeast Asia 12kV Medium Voltage Switchgear​
    Southeast Asia’s rapidly growing power demand (GDP growth >5% annually) combined with extreme climatic conditions—high temperature, humidity, and salt spray corrosion—necessitates balancing lifecycle costs with climate resilience in switchgear selection. This article analyzes the optimal cost-performance solutions between GIS and AIS.​I. GIS vs. AIS Cost Comparison Model (Southeast Asia Context)​​​1. Initial Investment Costs​2. Long-Term Operational Costs​​GIS Advantages:Ext
    06/12/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.