• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


SF6-free MV air-insulated switchgear

  • SF6-free MV air-insulated switchgear

Key attributes

Brand Schneider
Model NO. SF6-free MV air-insulated switchgear
Rated voltage 12/17.5kV
Rated normal current 1250A
Rated frequency 50/60Hz
Rated short circuit breaking current 25kA
Series AirSeT

Product descriptions from the supplier

Description

Product Overview

 By integrating sustainable air insulation technology, proven vacuum breaking solutions, and digital connectivity, the SM AirSeT series is an advanced SF6-free medium-voltage switchgear for indoor applications.

  • Compliance to IEC/UTE standards

    Designed and tested to comply with IEC 62271 series, UTE NFC standards, and RoHS/REACH requirements.

  • ISO 9001 certification

    Designed and manufactured in a facility certified by ISO 9001, with Green Premium sustainability certification.

  • High safety construction

    Internal arc protection compliant with IEC 62271-200 Appendix A, supporting up to 20kA 1s withstand capability.

Main Features

  • SF6-free sustainability - Adopts pure air insulation and Shunt Vacuum Interruption (SVI) technology, GWP=0, no toxic by-products, reducing carbon footprint throughout the lifecycle.

  • Native digital connectivity - Equipped with built-in sensors for thermal/environmental monitoring, QR code access to Digital Logbook, compatible with EcoStruxure Asset Advisor for predictive maintenance.

  • Enhanced safety - 3/4-side internal arc protection (IAC: A-FL/A-FLR), voltage presence indicator, and intuitive interlocking, ensuring operator and equipment safety.

  • Modular flexibility - Harmonized cubicle design with multiple functional units (switching, protection, metering), easy expansion without civil engineering modification.

  • Long service life - 40-year lifespan supported by CompoDrive operating mechanism and Schneider's self-developed vacuum interrupters, mechanical endurance up to 10,000 operations.

Technical Parameters

Project Unit Data
Rated voltage kV 7.2 12/17.5 24
Rated current A 400-630 630-1250 630-1250
Rated frequency Hz 50/60 50/60 50/60
Rated insulation level        
Rated power frequency withstand voltage (1min, effective value) kV 20 28/38 50
Rated lightning impulse withstand voltage (BIL, peak value) kV 60 75/95 125
Rated short circuit breaking current kA 12.5/16 20 25
Rated short time withstand current (1s) kA 12.5/16 20 25
Rated peak withstand current (peak values) kA 31.5/40 50 63
Operating mechanism type   CompoDrive (CDT/CD1/CD2) CompoDrive (CDT/CD1/CD2) CompoDrive (CDT/CD1/CD2)
Rated operating sequence   O-0.3s-CO-180s-CO O-0.3s-CO-180s-CO O-0.3s-CO-180s-CO
Electrical endurance level E2 (IEC 62271-103) E2 (IEC 62271-103) E2 (IEC 62271-103)
Mechanical endurance No of times 10000 10000 10000
Rated auxiliary control voltage V AC220/110, DC24/48/110 AC220/110, DC24/48/110 AC220/110, DC24/48/110
Opening time ms ≤60 ≤60 ≤60
Closing time ms 35~70 35~70 35~70
Enclosure protection level   IP55 IP55 IP55
Internal arc withstand level   A-FL 12.5kA 1s A-FLR 16kA 1s A-FLR 20kA 1s

 Application Scenarios

  • 24kV and below indoor medium voltage secondary distribution systems;

  • Circuit control and protection of commercial buildings, industrial plants, and utility substations;

  • Critical facilities such as data centers, hospitals, and airports requiring high reliability;

  • Sustainable energy projects and smart grid applications with low-carbon requirements.

Dimension (Core Cubicle Type)

Cubicle Type Height (mm) Width (mm) Depth (mm) Weight (kg)
IM (Switch Unit) 1600 375/500 1030/1120 137/147
DMVL-A (Circuit Breaker Unit) 1600 750 1220 407
NSM (Automatic Transfer Unit) 2050 750 1030 297
FAQ for
Q: What is the insulation principle of gas-insulated switches?
A:

Insulation Principle:

  • In an electric field, the electrons in SF₆ gas molecules are slightly displaced from the nuclei. However, due to the stability of the SF₆ molecular structure, it is difficult for electrons to escape and form free electrons, resulting in high insulation resistance. In GIS (Gas-Insulated Switchgear) equipment, the insulation is achieved by precisely controlling the pressure, purity, and electric field distribution of the SF₆ gas. This ensures a uniform and stable insulating electric field between the high-voltage conductive parts and the grounded enclosure, as well as between different phase conductors.

  • Under normal operating voltage, the few free electrons in the gas gain energy from the electric field, but this energy is not sufficient to cause collision ionization of the gas molecules. This ensures the maintenance of the insulating properties.

Q: What are the core advantages of air insulated technology compared to traditional SF6 switchgear?
A:


The core advantages are focused on environmental protection, safety, and full lifecycle costs: firstly, with zero Global Warming Potential (GWP), it completely replaces SF6 gas, which has a greenhouse effect 24300 times that of CO ₂, and has no toxic decomposition by-products; The second is to adopt dry air insulation+vacuum disconnection (SVI) technology, which does not require gas recovery, detection, and replenishment, reducing later operation and maintenance costs; The third is that the insulation medium can be directly discharged into the atmosphere, making the end of life treatment simpler and in line with the requirements of low-carbon projects.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 400000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 400000000
Services
Business Type: Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.