• Single Phase Active Electronic Reactive Fcatory Electricity Meter
  • Single Phase Active Electronic Reactive Fcatory Electricity Meter
  • Single Phase Active Electronic Reactive Fcatory Electricity Meter
Single Phase Active Electronic Reactive Fcatory Electricity Meter
$90.00
Model
SRMA-230/5(60)-3
SRMA-230/5(100)-3
SRMA-230/5(80)-3
SRMA-230/5(50)-3
SRMA-230/5(40)-3
SRMA-230/5(30)-3
SRMA-230/5(30)-2
SRMA-230/5(40)-2
SRMA-230/5(50)-2
SRMA-230/5(80)-2
SRMA-230/5(100)-2
SRMA-230/5(60)-2
SRMA-230/5(60)-1
SRMA-230/5(100)-1
SRMA-230/5(80)-1
SRMA-230/5(50)-1
SRMA-230/5(45)-1
SRMA-230/5(40)-1
SRMA-230/5(32)-1
SRMA-230/5(30)-1
Basic info
Brand Wone
Model NO. Single Phase Active Electronic Reactive Fcatory Electricity Meter
Rated voltage 230V
Rated normal current 5(60)A
Rated frequency 50(Hz)
Methods of Communication RS485
Series D123031
Product Detail

Description

The meter cover and terminal cover are made of transparent PC materials, and the internal structure of the meter and the welding assembly process are all exposed to the user,which has higher requirements on the ability of the meter manufacturer. The meter case is designed with a programming key, which has a lead block. And the removal of the lead seal can press the programming button, which can set the parameters of the meter.

Features

  • Active and reactive energy measurement

  • Mounted mounting installation

  •  Can up to 60A. RS485.

  • IR and ZIGBEE communication.

  • Multi-tariff function.

  • Meter has 3.6V Lithium battery, which is used to support multi-tariff function. And the precision of RTC is better than 0.5s/day.

  • LCD backlight allows the meter to be read in low light conditions.

  • With relay internal,which is used to remote control the meter connect and disconnect.

  • Terminal cover open detection.

  • With events records.

  • Over or Low voltage protection.

  • Electricity larceny prevention.

  •  Reactive energy can be measured.

  •  Degree of Protection: IP51 (indoor meter).

Specifications

Main
Range D123031
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(60)A

Rated Voltage

230V

Network Frequency 50Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

3200imp/kWh(LED)   

Maximum value measured 99999.99kWh
Tariff input Multi-tariff
Communication port protocol ---
Communication port support RS485/IR /ZIGBEE
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode ---
Mounting Support -----
Connections - terminals

-------

Standards

IEC62052-11/IEC62053-21



Environment
IP degree of protection

IP51

Relative humidity ≤75%
Ambient air temperature for operation -20…65 °C
Ambient Air Temperature for Storage --20…65 °C
Operating altitude ---
Dimensions 120*173.5*55mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 57mm
Package 1 Width 175mm
Package 1 Length 122mm
Package 1 Weight 1.000kg



Connection Diagram


image.png


Dimensions


image.png









Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
How is the contradiction between the small grounding residual current and the neutral point displacement voltage exceeding the standard resolved?
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should be
Edwiin
07/28/2025
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
Power Supply Design of the Group Testing Device for Special Transformers in Electrified Railways
1 Hardware Design of Tester Power SupplyThis device uses a standard small - signal generating device to generate small - current signals with the required frequency and phase angle. Then, through the amplifying circuit and phase - modulating circuit, the working power supply is generated.1.1 Power Frequency Sine Wave Small - Current Signal Generating DeviceThe sine wave generating circuit is mainly composed of the waveform generating chip MAX038 produced by MAXIM Corporation of the United States
Ron
07/28/2025
Analysis of Testing Methods for Turns Ratio and Connection Mode of Special Transformers
Analysis of Testing Methods for Turns Ratio and Connection Mode of Special Transformers
1 Error Analysis of Traditional Turn Ratio Testing MethodsThe QJ35 turn ratio bridge and other single-phase-phase-based testers all use the double-voltmeter principle. The QJ35, however, eliminates power supply fluctuation interference via bridge balance. For three-phase transformer ratio testing with a single power supply, corresponding terminals must be shorted and data converted, turning three-phase tests into independent single-phase measurements, with √3 Yd conversion based on connect
Felix Spark
07/28/2025
What are the production processes of special transformers?
What are the production processes of special transformers?
A certain special transformer manufacturing enterprise, which has been producing special transformers such as split - phase - shifting rectifier transformers, rectifier transformers for electrolysis, and transformers for submerged arc furnaces for more than 20 years. Now, an evaluation is made on the production process flow and its characteristics of the special transformers after the company's transformation.1.Production Process Flow Chart of Special TransformersThe production of special transf
Leon
07/28/2025
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!