VD4 MV Vacuum Circuit Breakers

  • VD4 MV Vacuum Circuit Breakers
  • VD4 MV Vacuum Circuit Breakers

Key attributes

Brand ROCKWILL
Model NO. VD4 MV Vacuum Circuit Breakers
Rated voltage 24kV
Rated normal current 630A
Rated frequency 50/60Hz
Series VD4

Product descriptions from the supplier

Description

Descaiption

VD4 MV Vacuum Circuit Breakers are high-reliability switching solutions for 12kV–40.5kV medium-voltage distribution networks. As standard and versatile equipment, they suit all primary applications, including power utilities, industrial parks, renewable energy stations, and commercial buildings, perfectly supporting smart grid and distribution automation upgrades. Featuring 30,000 overhaul-free mechanical operations across most ratings, they drastically reduce maintenance costs. Equipped with a modular spring-operated actuator for easy operation, the fully sealed vacuum interrupter ensures excellent arc-extinguishing and insulation performance, enabling stable work in harsh environments like high humidity, dust, and extreme temperatures. With a complete, standardized range of accessories and spare parts, installation and replacement are simplified. Compliant with IEC/ANSI standards, they support remote control and intelligent monitoring, enhancing power supply reliability and operational safety.

Feature

  • Perform 30,000 overhaul-free mechanical operations on most ratings.
  • Modular spring-operated mechanical actuator ensuring easy operation.
  • Have a complete range of accessories to satisfy all installation requirements.
  • Have a standardized range of accessories and spare parts.

Technical Parameters

Rated voltage 12...24 kV
Withstand voltage at 50Hz 38...65 kV / 1 min
Impulse withstand voltage 75...125 kV
Rated frequency 50/60 Hz
Rated normal current 630...4000 A
Rated breaking capacity 20...40 kA
Rated 4 s withstand current 20...40 kA
Making capacity 50...100 kA
Operation sequence O-0.3 s-CO-15 s-CO
Opening time 33...60 ms
Arcing time 10...15 ms
Total breaking time 43...75 ms
Closing time 50...80 ms
Operating temperature -15 ... +40 °C
Operating voltage 24...250 V
Secondary withstand voltage 2000V 50Hz (1 min)
Circuit breaker class E2, C2, M2.
  • Provided customized manufacture
  • Whole solutions for design, assembly, test...
  • Accountable solution for safety and reliability
  • Wide range offering, easy business and convenient installation

Documentation Resource Library
Restricted
VD4 MV Vacuum Circuit Breakers
Brochure
English
Consulting
Consulting
FAQ
Q: What are the key advantages of VD4 MV Vacuum Circuit Breakers for medium-voltage grids?
A:

 VD4 MV vacuum circuit breakers offer 30,000 overhaul-free mechanical operations, modular spring-actuated design for easy use, and sealed vacuum interrupters. They excel in harsh environments, comply with IEC/ANSI standards, and support distribution automation.

Q: What applications are VD4 MV Vacuum Circuit Breakers suitable for?
A:

VD4 medium-voltage vacuum circuit breakers are ideal for 12kV–40.5kV systems, including power utilities, industrial parks, renewable energy stations, and commercial buildings, enhancing power supply reliability and grid safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.