• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Wind Power Equipment Box-type Transformer(Prefabricated Substation)

  • Wind Power Equipment Box-type Transformer(Prefabricated Substation)

Key attributes

Brand ROCKWILL
Model NO. Wind Power Equipment Box-type Transformer(Prefabricated Substation)
Rated voltage 40.5kV
Series Compact Substation

Product descriptions from the supplier

Description

Product overview:

  • Wind turbine substation is to send the electricity generated by the wind turbine to the grid or users, so as to complete the task of wind power generation. Friends WONE wind box products is the transformer, oil-immersed load switch and high voltage fuse is installed in the fuel tank, transformer oil as the medium of electrical insulation products and cooling medium and low voltage side configuration necessary electric protection components, products with intelligent, reliable operation, small volume, light weight and easy installation and use, etc.

  • Rated AC frequency 50Hz/60HZ, input voltage 0.8kV, 0.9kV, maximum working voltage up to 40.5kV, withstand lightning strike 200KV.

  • Main application: Wind power industry.

  • Standards: IEC61400 series, GB/T17467, etc.

Product advantages:
Leading technology:

  • Standard anti-corrosion and salt spray environment scheme, meet the strict environmental requirements of the site.

  • Can be composed of vacuum circuit breaker and sulfur hexafluoride ring network cabinet or all sulfur hexafluoride ring network cabinet.

  • Prefabricated, electrified and touchable silicone rubber cable end ensures personal safety.

  • Can be equipped with multiple SF6 load switches, flexible and diverse wiring modes, branch outlet up to eight circuits.

  • Compact design, optional lightning arrester, short circuit fault indicator. Current limiting fuse.

  • The relative pressure of SF6 in the air pack should not exceed 1.4bar. Air leakage is not more than 1%/ year, 30 years maintenance free.

  • Box type opening and closing should have perfect five anti-interlocking function to ensure personal safety .

Enclosure:

  • The whole use of 1.5-2mm double layer stainless steel box, service life can reach more than 30 years.

  • Laser CNC equipment cutting, drilling, bending, ensure processing accuracy.

  • External electrostatic epoxy powder coating, 30 years of paint.

  • Box surface has good anti-theft, box has IP3X protection, etc.

Processing and assembly:

  • Dust-free workshop to ensure insulation.

  • Assembly workers must be trained for at least 6 months.

  • Automatic terminal crimping machine for secondary wiring to ensure reliable wiring.

  • Bolt reinforcement using power tools to ensure proper torque.

  • The copper busbar is CNC cutting, punching and bending to ensure accuracy.

  • All kinds of experimental tests before delivery, to ensure the normal operation of equipment.

Product parameters:

  • Capacity: 2500kVA American box.

  • Rated voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 35kV.

  • Maximum operating voltage (kV) 38.5kV.

Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90

  •  Altitude (≤m) : 1000.

  •  solar radiation intensity (W/cm2) : 0.1.

  • Maximum ice thickness (mm) : 10.

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35.

  • Ground horizontal acceleration (M/S2) : 2.

  • Installation place: outdoor; 8. Pollution grade: ⅲ.

Ordering instructions:

The customer shall provide the following information:

  • Main loop scheme diagram, secondary loop system diagram and auxiliary circuit control mode.

  • Equipment layout and distribution room layout.

  • Brand and model of main electrical components of the equipment.

  • Incoming and outgoing lines.

  • Other special requirements can be negotiated with WONE you Electric.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.