Model
WSⅢDL800/35-5x5-10x10
WSⅢDL630/35-5x5-10x10
WSⅢDL400/35-5x5-10x10
WSⅢDL200/35-5x5-10x10
WSⅡDL800/35-6x5-10x9
WSⅡDL630/35-6x5-10x9
WSⅡDL40035-6x5-10x9
WSⅡDL200/35-6x5-10x9
WSLⅢDL800/10-5x5-10x10
WSLⅢDL630/10-5x5-10x10
WSLⅢDL400/10-5x5-10x10
WSLⅢDL200/10-5x5-10x10
WSLⅡDL800/10-6x5-10x9
WSLⅡDL400/10-6x5-10x9
WSLⅡDL630/10-6x5-10x9
WSLⅡDL200/10-6x5-10x9
Basic info
Brand Transformer Parts
Model NO. WSLD Series electric cage tap changer
Rated voltage 10kV
Rated normal current 630A
Methods of regulation Neutral voltage regulation
number of taps 5~10
number of position 5~10
Series WSLD Series
Product Detail

Overview

WSLD Series Non-excitative tap-changer belongs to a cage-like structure without oil container, which can be directly installed in the oil tank of the transformer. According the different outline structures, the switch can be divided into vertical, bell and horizontal types.

outline

 

Switch type

Rated 

Voltage 

kV

Position of 

Voltage regulation

Installation Dimension

L1

L2

H1

H2

WSLⅡDL200 - 400/10 - 6X5 - 10X9 F

10

Central part

210

110

540

720

WSLⅢDL200 - 400/10 - 5X5 - 10X10 F

10

Neutral Point

210

110

540

720

WSLⅡDL630 - 800/10 - 6X5 - 10X;9 F

10

Central part

230

130

610

790

WSLⅢDL630 - 800/10 - 5X5 - 10X0 F

10

Neutral Point

230

130

610

790

WSLⅡDL200 - 400/35 - 6X5 - 10X9 F

35

Central part

275

170

710

890

WSLⅢDL200 - 400/35 - 5X5 - 10X10 F

35

Neutral Point

275

170

710

890

WSLⅡDL630 - 800/35 - 6X5 - 10X9 F

35

Central part

300

195

810

990

WSLⅢDL630 - 800/35 - 5X5 - 10&X10 F

35

Neutral Point

310

200

815

990

 

Switch type

Rated 

Voltage 

kV

Position of 

Voltage regulation

Installation Dimension

L1

L2

H1

H2

WSLⅡDL200~400/10 - 11X10~14X13 F

10

Central part

210

110

540

720

WSLⅢDL200~400/10 - 11X11~14X14 F

10

Neutral Point

210

110

540

720

WSLⅡDL630~800/10 - 11X10~12X11 F

10

Central part

230

130

610

790

WSLⅢDL630~800/10 - 11X11~12X12 F

10

Neutral Point

230

130

610

790

WSLⅡDL200~400/35 - 11X10~14X13 F

35

Central part

275

170

710

890

WSLⅢDL200~400/35 - 11X11~14X14 F

35

Neutral Point

275

170

710

890

WSLⅡDL630~800/35 - 11X10~12X11 F

35

Central part

300

195

810

990

WSLⅢDL630~800/35 - 11X11~12X12 F

35

Neutral Point

310

200

815

990

 



Switch type

Rated

Voltage 

kV

Position of 

Voltage-regulation

Installation Dimension

L1

L2

H1

H2

WSⅡJLDL200~630/10 - 4×3~10×9 Y

10

Central part

150

110

480

716

WSⅡJLDL200~630/10 - 5×5~10×10 Y

10

Neutral Point

150

110

480

716

WSⅡJLDL800/10 - 6×5~10×9 Y

10

 Central part

170

130

550

786

WSⅡJLDL800/10 - 5×5~10×10 Y

10

Neutral Point

170

130

550

786

WSⅡJLDL200~630/35 - 6×5~10×9 Y

35

Central part

210

170

650

886

WSⅡJLDL200~630/35 - 5×5~10×10 Y

35

Neutral Point

210

170

650

886

WSⅡJLDL800/35 - 6×5~10×9 Y

35

Central part

240

195

750

986

WSⅡJLDL800/35 - 5×5~10×10 Y

35

Neutral Point

240

195

750

986



Switch type

Rated 

Voltage 

kV

Position of 

Voltage-regulation

Installation Dimension

L1

L2

H1

H2

WSLⅡDL200~400/10 - 11×10~14×13 F

10

Central part

210

110

540

720

WSLⅢDL200~400/10 - 11×11~14×14 F

10

Neutral Point

210

110

540

720

WSLⅡDL630~800/10 - 11×10~12×11 F

10

Central part

230

130

610

790

WSLⅢDL630~800/10 - 11×11~12×12 F

10

Neutral Point

230

130

610

790

WSLⅡDL200~400/35 - 11×10~14×13 F

35

Central part

275

170

710

890

WSLⅢDL200~400/35 - 11×11~14×14 F

35

Neutral Point

275

170

710

890

WSLⅡDL630~800/35 - 11×10~12×11 F

35

Central part

300

195

810

990

WSLⅢDL630~800/35 - 11×11~12×12 F

35

Neutral Point

310

200

815

990


Switch type

Rated 

Voltage 

kV

Position of

 Voltage-regulation

Installation Dimension

L1

L2

H1

H2

WSL I DL 125~630/10 - 5×5~8×8   Y

10

Terminal  port

150

110

480

716

WSL I DL 125~630/10 - 9×9~11×11 Y

10

Terminal  port

150

150

600

836

WSL I DL 125~630/35 - 5×5~8×8   Y

35

Terminal    port

210

170

650

886

WSL I DL 125~630/35 - 9×9 Y

35

Terminal    port

210

210

780

1016

 


Switch type

Rated 

Voltage

kV

Position of 

Voltage-regulation

Installation Dimension

L1

L2

H1

H2

WSL I DL 200~630/10 -   10×10~13×13 Y

10

Terminal    port

150

150

600

836

WSL I DL 630/10 - 10×10~13×13   Y

10

Terminal  port

150

150

600

836

WSL I DL 200~400/35 -   10×10~13×13 Y

35

Terminal    port

210

210

780

1016

WSL I DL 630/35 - 10×10~11×11   Y

35

Terminal    port

210

210

780

1016


Switch type

Rated 

Voltage

kV

Position of 

Voltage-regulation

Installation Dimension

L1

L2

H1

H2

WSLNDL200~630/10 - 2×2 Y

10

Y / △

150

110

480

716

WSLNDL800/10 - 2×2 Y

10

Y / △

170

130

550

786

WSLNDL200~630/35 - 2×2 Y

35

Y / △

210

170

650

886

WSLNDL800/35 - 2×2 Y

35

Y / △

240

195

750

986

 

Switch type

Rated Voltage kV

Position of 

Voltage-regulation

Installation Dimension

L1

L2

H1

H2

WSL V DL200~630/10 - 4×2 Y

10

Series-Parallel

150

110

480

716

WSL V DL800/10 - 4×2 Y

10

Series-Parallel

170

130

550

786

WSL V DL200~630/35 - 4×2 Y

35

Series-Parallel

210

170

650

886

WSL V DL800/35 - 4×2 Y

35

Series-Parallel

240

195

750

98

application

This series consists of an electric transmission mechanism, a switch body, and an electric controller. It is designed for use in oil-immersed transformers with a maximum equipment voltage of 40.5 kV or lower and a rated current of 630A or lower. The tap and switch functions can be operated electrically or manually when the transformer is de-energized.

 

If you need to know about more product; welcome contact us.→

Know your supplier
Transformer Parts
As a key component in power systems, the stable operation of transformers relies on high-quality accessories. Wone specializes in the sales and supply of transformer accessories, delivering high-quality products and fast response services through an efficient and professional supply chain system. Core Strengths Comprehensive Product Range: Includes insulation materials, cooling components, protection devices, and various structural parts to meet diverse needs. Global Supply Chain Network: Integrates high-quality supplier resources to ensure product stability and reliable delivery schedules. Smart Logistics Management: Utilizes information systems for full-process tracking, improving delivery efficiency and transparency. Professional Technical Support: Offers product selection advice, application consulting, and after-sales maintenance to ensure smooth project execution. Commitment to Sustainability: Prioritizes eco-friendly materials and energy-efficient products, fulfilling corporate social responsibility. Wone is committed to building an efficient, reliable, and sustainable supply chain for transformer accessories, supporting the stable development of the power industry.
Main Categories
Electrical fittings
Business Type
Design/Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Documents
Restricted.
WSLD Series electric cage tap changer manual
Manual English
Consulting
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!