• Zinc oxide surge arrester for lightning protection
Zinc oxide surge arrester for lightning protection
discuss personally
Model
YH-5W-6
YH-5W-24
YH-5W-15
YH-5W-6
Basic info
Brand Wone
Model NO. Zinc oxide surge arrester for lightning protection
Rated voltage 6kV
Continuous operating Voltage 5.1kV
Series Surge Arrester
Product Detail

Description:

Zinc oxide surge arrester is a lightning protection device with superior protection performance, light weight, pollution resistance and stable performance. It mainly uses the good non-linear volt-ampere characteristics of zinc oxide to make the current flowing through the surge arrester at normal working voltage very small (microamp or milliampere level); when the overvoltage acts, the resistance drops sharply,venting the overvoltage Energy to achieve the effect of protection. The difference between this kind of lightning arrester and the traditional lightning arrester is that it has no discharge gap, and uses the non-linear characteristics of zinc oxide to discharge and break.

General :

  • Ratings:0.22-500KV (porcelain),0.22-220KV(composite)

  • Application.for protection of power transmission& distribution system from over-voltage.

Features:

  • Silicone polymer housing composite metal oxide surge arrester and porcelain housing metal Oxide surge arresters are available.

  • Easy installation and maintenance.

  • Good sealing capability to ensure reliable operation.

  • Protection and reliability of the surge arrester have been greatly enhanced.

Type designation:

image.png

Working condition:

  • Ambient air temperature:-40℃—+40℃.

  • Altitude: <=2000m.

  • Frequency: 48Hz~62Hz.

  • Power frequency voltage applied between terminals of surge arrester must not exceed continuous operating voltage of surge arrerter.

  • Earthquake intensity is less than 8 degree.

  •  Max. Wind speed is 35m/s.Aawifflii Surge arrester.

Main techical parameter:

Metal oxide Polymer Housing (Gapless)type Surge Arrester for A.C System(5kA series)

企业微信截图_17339000416849.png

企业微信截图_17339001468386.png

 Metal Oxide Polymer Housing (Gapless) type Surge Arrester tor A.C. System (10KA series)

企业微信截图_17339003233255.png


Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (20KA series)

企业微信截图_17339005212737.png

Metal Oxide Porcelain Housing (Gapless) type Surge Arrester for A.C. System (5KA series)

企业微信截图_17339007891245.png

Metal Oxide Polymer Housing (Gapless) type Surge Arrester for A.C. System (10KA series)

image.png

企业微信截图_17339011202607.png


Metal Oxide Polymer Housing (Gapless)type Surge Arrester for A.C. System (20KA series)

企业微信截图_1733901352801.png

When order,please indicate the detailed information as below listed:

  • Anti-contamination degree and creepage distance.

  • Any special requirement.

  • Accessories.

  • Max. System voltage.

  • Rated voltage or Max.continuous operating voltage.

  • Nominal discharge current.

  • Type of housing material.

How does the zinc oxide arrester for lightning protection work?

Normal Operating Voltage:

  • Under normal operating voltage, the zinc oxide varistor discs present a high-resistance state, allowing only a minimal current—typically in the microampere or milliampere range—to flow through the surge arrester. At this time, the arrester acts like an insulator, having virtually no impact on the system's normal operation.

Overvoltage Event:

  • When struck by lightning or when overvoltage occurs in the system (such as from lightning surges or switching overvoltages), the resistance of the zinc oxide varistor discs drops sharply, forming a low-resistance path. This allows the energy generated by the overvoltage to rapidly discharge through the arrester into the ground, thereby limiting the voltage on the protected equipment to within a safe range and effectively protecting the insulation of electrical devices from overvoltage damage.

Post-Overvoltage Recovery:

  • Once the overvoltage event has passed, the zinc oxide varistor discs quickly return to their high-resistance state, restoring normal power supply to the system and preparing for any potential future overvoltage events.


Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!