Low-Noise, Energy-Efficient Dry-Type Transformer Solutions for Premium Commercial Buildings

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Ⅰ. Core Pain Points
Urban CBD supertall buildings face two critical challenges:
• ​Noise Control Difficulty:​ Traditional transformers' no-load noise (>55dB) disrupts premium office environments, violating green building acoustic standards.
• ​Premium Space Constraints:​ Electrical room costs exceed ¥100,000 per square meter; large traditional transformers encroach on core functional areas.

Application Scenarios:​ 500m+ supertall landmarks, LEED Gold-certified office towers, international financial centers.

II. Customized Solution Design

1. Acoustic Optimization System (Noise ≤45dB(A))

​Technical Module

​Innovative Design

​Performance Gain

Magnetic Noise Reduction

Stepped-lap core joints + 27QG110 high-permeability silicon steel

≤45dB(A) no-load noise ▼ 18% below national standard

Vibration Control

Resilient shock pads + Nano-fiber sound-absorbing panels

8dB structural noise transmission reduction

​▶ Achieved Outcome:​​ Operating sound pressure level lower than a library environment (50dB), compliant with ISO 3744 indoor acoustic certification.

2. Space Compression Technology (+20% Power Density)

  • Coil Foil Winding Process:​ 0.05mm ultra-thin copper foil lamination technology
    → 15% eddy current loss reduction
  • 3D Cooling Channels:​ Vertical air ducts + honeycomb radiators
    → 30% thermal efficiency improvement

Footprint Comparison (2500kVA):

  • Traditional Transformer:​ ≥ 3.8m²
  • This Solution:​ 3.0m² ▼ 21% space saving

3. Fire Safety Assurance (Zero Hazardous Emissions)

  • Insulation System:​ UL-certified CERADUR® eco-friendly resin
  • Fire Resistance:​ Passes 950℃ open flame test
  • Safety Certs:​ IEC 60726 / IEC 60076-11
    ■ ​Key Breakthrough:​ Zero halogen gas emission during combustion (HCl < 0.1%), preventing secondary toxic hazards in fires.

III. Quantified Customer Value

​Dimension

​Benefit Metrics

​Application Value

Economic Value

30% reduction in electrical room footprint

Saves ≈100m² per 10,000m² building → ¥3M/year added leasable area

Certification Value

+15 points towards LEED credits

40% increase in Gold certification success rate

Operational Cost

12% lower load loss (IEC 60076)

≈50,000 kWh annual power savings per 2500kVA unit

IV. Target Application Scenarios

  1. New Supertall Landmarks:​ Complies with GB 50045 supertall building fire codes.
  2. Premium Commercial Retrofit:​ Enables capacity upgrade without expanding electrical rooms.
  3. Data Center Backup Power:​ Certified compliant with IEEE 519 harmonic current limits.

Success Case:​ A 380m Shanghai financial center implementing this solution achieved LEED Gold certification, with BMS-measured noise levels at 43.7dB(A).

07/04/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.