• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Voltage Transformer Solution: Dedicated Solution for Compact Medium Voltage Switchgear

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Core Positioning:​ Provides a high-performance, ultra-compact voltage measurement solution for medium voltage switchgear (e.g., KYN28) with severely limited space, achieving installation flexibility unattainable by traditional designs.

Technical Approach: Ultra-Small Space Adaptation
Traditional Voltage Transformers (VTs) are bulky and difficult to fit into the instrument compartments of modern compact switchgear like KYN28. This solution achieves revolutionary miniaturization through the following innovations:

  1. Structural Innovation - Extremely Compact Physical Design
    • Dry-Type Epoxy Resin Cast Structure:​ Utilizes advanced integral casting technology, with an insulator diameter of just Φ90mm, setting an industry-leading limit for radial dimensions.
    • Three-Phase Common-Enclosure Design:​ Breakthrough integration of A/B/C three-phase voltage sensing units into a single sealed enclosure, optimizing overall dimensions to 250mm (L) × 180mm (W) × 120mm (H), completely eliminating redundant inter-phase space.
    • C-GIS Dedicated Amorphous Alloy Core:​ Employs a specially developed amorphous alloy core for Compact Gas-Insulated Switchgear (C-GIS). This material offers high permeability, low iron loss, and excellent temperature stability, meeting measurement accuracy requirements within an extremely small volume – a core material foundation enabling ultra-compactness.
  2. Electrical Performance - High-Standard Reliability Assurance
    • Rated Voltage:​ 12kV (Suitable for mainstream MV systems)
    • Insulation Strength:
      • Power Frequency Withstand Voltage: 42kV / 1min (Far exceeding standard requirements)
      • Creepage Distance: ≥ 25mm/kV (High pollution flashover resistance, suitable for harsh environments)
    • Low Partial Discharge:​ Partial Discharge Level < 5pC (Extremely low level), ensuring high long-term operational reliability and lifespan, meeting stringent power grid equipment condition monitoring requirements.
    • (Other key parameters such as accuracy class, rated burden, etc., to be specified based on application)
  3. Core Advantage: Transformative Space Savings
    • Volume Reduction ≥ 60%:​ Achieves over 60% volume compression compared to traditional split-core or larger common-enclosure VTs, reaching top industry standards.
    • Seamless Integration into KYN28 Cabinet:​ Can be directly installed within the instrument compartment of mainstream switchgear like KYN28, eliminating the need for extra space expansion or cabinet structure modifications. Solves the critical pain points of traditional VTs being too large to fit inside or requiring valuable space in cable/breaker compartments.
    • Simplified Installation & Maintenance:​ The single integrated device greatly simplifies wiring and installation processes, reducing operational complexity.
07/07/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application