• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Specialized Voltage Transformer Solution for High-Speed Railway AT Power Supply System: Focused on Strong EMI Immunity

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Specialized Voltage Transformer Solution for High-Speed Railway AT Power Supply System: Focused on Strong EMI Immunity

The electromagnetic environment of the high-speed railway AT (Auto-Transformer) power supply system is extremely complex. Strong electromagnetic interference (EMI) directly affects the measurement accuracy of voltage transformers and system reliability. This solution specifically targets this core challenge by developing a dedicated voltage transformer that meets the 27.5kV single-phase power supply standard, providing a solid foundation for energy metering and relay protection on high-speed railways.

Core Technological Breakthrough: Triple Defense Against EMI Storms

  1. μ-Metal Alloy Triple Electromagnetic Shield:
    • Structure:​ Utilizes three independent inner, middle, and outer shielding shells constructed from high-permeability μ-metal alloy.
    • Efficacy:​ Effectively absorbs/blocks low-frequency strong magnetic field interference generated by the 27.5kV overhead contact line and high-frequency transient EMI caused by system switching operations. The core sensing element is effectively shielded, ensuring signal purity.
  2. 27.5kV Dedicated Single-Phase Structural Design:
    • Precise Matching:​ Magnetic circuit and windings are deeply optimized for the 27.5kV power-frequency single-phase characteristics, eliminating phase-to-phase crosstalk effects and enhancing absolute accuracy of single-point measurement.
    • Stability:​ Special materials and processes significantly reduce core saturation risk, guaranteeing transient response speed and waveform reproduction capability.
  3. Vibration Resistance Enhancement (5-200Hz, 2g Acceleration):
    • Simulation-Driven:​ Utilizes FEA (Finite Element Analysis) to simulate complex vibration spectra at trackside locations (including characteristic vibrations induced by passing CRH trains).
    • Reinforcement Solution:​ Internal core components are secured using elastic silicone potting. The external housing employs high-strength alloy and anti-vibration structural elements, ensuring zero connection loosening/displacement under long-term mechanical impact for consistent accuracy.
  4. CRH Standard Communication Interfaces (RJ45 + TNC):
    • Dual Assurance:​ The RJ45 interface provides standardized digital communication based on mature Ethernet physical layer. The redundantly designed TNC interface (coaxial connector) ensures highly reliable transmission of critical analog/digital signals under extreme interference.
    • Immunity Capability:​ Interface circuits feature built-in multi-layer EMC protection (TVS, filtering). Ports comply with the rigorous IEC 61000-4 series standards for surge and EFT immunity.

Key Performance Indicators: Hardware Commitment to Accuracy & Reliability

Parameter

Performance Indicator

Test Standard / Notes

Rated Voltage

27.5kV / √3V (Phase Voltage)

-

Accuracy Class

0.2S

Complies with GB/T 20840.1 / IEC 61869-1

Temperature Drift

≤ ±0.002%/K

Stability throughout full operating range (-40℃ ~ +70℃)

Electrical Fast Transient (EFT)

4kV (Peak)

Meets IEC 61000-4-4 Level 4

Power Frequency Withstand

Per GB/T 20840 / IEC standards

-

Partial Discharge

≤ 10pC @ 1.2 Ur

IEC 60270

Environmental Resilience: The Robust Guardian at Trackside

  • Protection Class:​ IP65 - Comprehensive protection against dust ingress and high-pressure water jets, impervious to rain, snow, wind, and sand.
  • Operating Temperature:​ -40℃ ~ +70℃ - Wide-temperature materials and special processes selected to withstand extreme seasonal climate challenges across all regions of China, ensuring consistent performance.
  • Installation:​ Designed for trackside pole or compact substation environments, featuring a compact structure for easy installation and maintenance.
07/07/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.