Cable Environmental Protection and Sustainable Development Solution

Wone Store
2yrs + staff 1000+m² US$300,000,000+ China

1. Problem Background
With increasingly stringent global environmental regulations (e.g., EU RoHS, REACH directives) and the advancement of carbon neutrality goals, the environmental footprint throughout the entire lifecycle of electrical cables has become a core procurement criterion for users. Traditional cables face challenges including heavy metal pollution, non-biodegradable material overuse, and high-energy-consumption production, necessitating systemic green transformation.

2. End-to-End Sustainable Solutions
2.1 Eco-Material Innovation

​Material Category

​Solution

​Environmental Value

Conductor Material

Use high-purity recycled copper (recycling rate ≥99%) to reduce mining

40% lower carbon footprint, 60% higher resource circularity

Insulation/Sheath

Replace PVC with halogen-free flame-retardant polyolefin (HFFR) and bioplastics (e.g., PLA)

Non-toxic emissions during incineration; soil degradation cycle reduced to 3-5 years

Shielding Material

Substitute lead armor with aluminum-plastic composite tape

Eliminates heavy metal pollution risks; easier recycling separation

2.2 Green Manufacturing System
• ​Energy Control: Apply electromagnetic induction heating (35% lower energy consumption vs. traditional resistance heating)
• ​Waste Management: Instant crushing/pelletizing of scraps (98% in-plant reuse rate)
• ​Pollutant Control: VOCs emission concentration <20mg/m³ (50% stricter than national standards)

2.3 Lifecycle Management
• ​Product Design: Modular structures (e.g., separable connectors) enable rapid disassembly/recycling
• ​Carbon Footprint Certification: Provide full lifecycle LCA reports compliant with ISO 14067
• ​Recycling System: Establish trade-in channels for used cables to form a "Production-Use-Recycling" closed loop

3. Technical Safeguards
• ​Testing & Certification: UL ECOLOGO®, TÜV Eco-Cable certified
• ​Digital Management: MES system for real-time monitoring of energy/emission metrics per process
• ​R&D Innovation: Jointly develop nano-modified cellulose insulation with universities (92% lab degradation rate)

4. Quantified Benefits Model

​Indicator

​Conventional Solution

​This Solution

​Improvement Range

Carbon emissions (per ton)

2.8t CO₂e

1.5t CO₂e

↓46.4%

Hazardous waste (per km)

35kg

8kg

↓77.1%

Recycled material content

<15%

≥65%

↑330%

5. Sustainable Development Roadmap

  1. 2025: Full product compliance with EU CPR Class B1ca environmental rating
  2. 2028: Factories powered by 100% renewable electricity; carbon-neutral processes
  3. 2030: Bio-based material utilization rate increased to 40%

This solution drives the cable industry's transformation from "gray energy-consumption" to "green gain" through material revolution, clean production, and circular economy synergies, supporting clients' ESG strategic objectives.

07/31/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.