High-Temperature Insulating Material Solution for Electric Furnace Transformers

Rockwill
17yrs 700++ staff 108000m²+m² US$150,000,000+ China

Background & Challenge
Electric furnaces operate for extended periods under harsh conditions involving high temperatures, dust, etc. Traditional transformer insulation materials experience accelerated aging in these environments, leading to insulation failure, reduced lifespan, and even unplanned furnace shutdowns, significantly impacting production efficiency.

Core Strategy
Implement a dual-pronged approach to ensure transformer reliability and long-term operation under extreme high temperatures:

  1. High-Performance High-Temperature Insulation System
  2. Enhanced Cooling Structure Design

Key Implementation Measures

1. Application of Special Insulating Materials

  • Conductor Insulation Upgrade:​ Utilize Class H (180°C) or higher temperature-resistant enamelled wires (e.g., polyimide, nano-composite coatings) to ensure winding insulation strength does not degrade under prolonged high temperatures.
  • Solid Insulation Reinforcement:​ Employ inorganic insulating paper (mica paper, NOMEX®, etc.) for interlayer/inter-turn insulation, replacing traditional organic materials. Tolerant to temperatures ≥220°C, eliminating carbonization risks.
  • High-Temperature Treatment of Structural Components:​ Upgrade auxiliary components (e.g., insulating bobbins, barriers) to high-temperature engineering plastics or laminated composite materials, achieving consistent high-temperature resistance throughout the entire insulation system.

2. Optimized Efficient Cooling System

  • Heat Dissipation Area Doubling Design:​ Significantly increase the surface area of enclosure cooling fins (over 30% more than conventional designs) and adopt corrugated tank structures to maximize natural convection cooling efficiency.
  • Intelligent Airflow Duct Configuration:​ Optimize internal airflow duct layout based on thermal simulation data to eliminate cooling dead zones. Pre-set forced air cooling duct interfaces for rapid integration with site fans when needed.
  • Heat Dissipation Surface Treatment:​ Apply high-emissivity thermal radiation coatings (emissivity ≥0.9) to cooling fin surfaces, enhancing thermal radiation efficiency by over 20%.

Expected Results

  • Enhanced Stability:​ Insulation system temperature class upgraded from Class B (130°C) to Class H (180°C) or higher, capable of withstanding ambient temperatures ≥70°C.
  • Extended Lifespan:​Transformer design life increased to 15-20 years (compared to 8-12 years for conventional electric furnace transformers), reducing equipment replacement costs.
  • Optimized Energy Efficiency:​ Thermal losses reduced by 8-12%, achieving overall operational efficiency improvement of ≥1.5%.

Solution Value Summary
This solution delivers a breakthrough through dual-path innovation – materials and structure – decisively resolving the critical pain point of transformer insulation aging caused by high-temperature environments. It provides round-the-clock reliable power supply assurance for electric furnace equipment in metallurgy, chemical processing, foundry, and related industries, significantly reducing the losses associated with unplanned downtime.

08/09/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.