Special Cable Solution for High-Voltage Transmission Networks

Wone Store
2yrs + staff 1000+m² US$300,000,000+ China

Application Scenarios
Urban power grid upgrades, power supply for large industrial parks, grid integration of renewable energy power stations, and other medium-to-short-distance, high-reliability power transmission scenarios.

Core Requirements
Excellent flame retardancy, compact structure for easy installation, strong corrosion resistance, and high mechanical stress resistance.

Solution

  • Material Upgrade:
    Use flame-retardant cross-linked polyethylene (FL-XLPE) as insulation material. A composite flame-retardant system of magnesium hydroxide/aluminum hydroxide achieves a flame retardancy rating compliant with IEC 60332-3 Class A standards.
  • Structural Optimization:
    • Conductor made of high-conductivity copper alloy with a segmental design to increase the fill factor to 93%.
    • Three-layer co-extruded shielding structure (semiconductor shielding layer + insulation layer + semiconductor shielding layer) ensures uniform electric field distribution.
    • Metal shielding layer adopts a composite structure of copper wire braiding + galvanized steel tape armor.
  • Protection System:
    • Outer sheath made of polyamide-polyurethane composite material, with chemical corrosion resistance meeting ISO 6722 standards.
    • Addition of a carbon nanotube reinforcement layer to enhance crush resistance (able to withstand ≥20 kN/m pressure).

Implementation Results
After application in a coastal industrial park project:

  • Cable installation density increased by 35%.
  • Failure rate reduced to 0.12 instances/100 km·year.
  • Expected service life extended to 35 years.
  • Passed electromagnetic compatibility tests per CISPR 22 standards.

Smart Monitoring Expansion Function
Optional distributed temperature sensing (DTS) and partial discharge monitoring modules enable real-time operational status monitoring, achieving a warning accuracy rate of ≥90%.

Note: This solution complies with standards such as GB/T 12706-2020 and IEC 60502-2. Customized designs are available based on specific engineering requirements.

09/10/2025
Recommended
Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
Dedicated Vacuum Contactor Solution for Port Shore Power Systems
I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
Vacuum Contactor Industrial Power Control Solutions
Application Background and Pain Point Analysis​In modern industrial manufacturing power control systems, traditional contactors exhibit significant limitations under specific operating conditions:• ​Frequent Start-Stop Operations: Traditional contactors have limited mechanical lifespan, with frequent operations leading to coil burnout and mechanical jamming.• ​Poor Adaptability to Harsh Environments: Contacts are prone to oxidation in dusty environments, resulting in increased contact
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.