What is the method for determining the induced electromotive force in a circuit with varying magnetic flux?

Encyclopedia
Field: Encyclopedia
0
China

The method for determining the induced electromotive force caused by a change in magnetic flux in a circuit usually follows Faraday's law of electromagnetic induction. Faraday's law of electromagnetic induction describes the induced electromotive force (EMF) due to changes in magnetic flux, as follows:


dc2b9103e4a8d58d6c54eae7caeb619e.jpeg


The meanings of the symbols are as follows:


  • E stands for induced electromotive force (volts, V).


  • N is the number of turns of the coil.


  • ΔΦB is the change in magnetic flux through the coil (unit: Weber, Wb).


  • Δt is the time (in seconds, s) required for the magnetic flux to change.



Application steps of Faraday's law of electromagnetic induction


  • Determine the magnetic flux: First you need to determine the magnetic flux through the coil. The magnetic flux ΦB can be calculated by the following formula:


23506bf764706400ae9e052e7d663ff5.jpeg


Here B is the magnetic induction intensity (unit: tesla, T), A is the effective area perpendicular to the direction of the magnetic field (unit: square meters, m²), and θ is the Angle between the direction of the magnetic field and the normal direction of the coil plane.


  • Calculate the change in magnetic flux: If the magnetic flux changes with time, you need to calculate the change in magnetic flux over a period of time ΔΦB= ΦB, final−ΦB,initial


  • Determine the time interval: Determine the time interval Δt required to change the magnetic flux.



  • Faraday's Law is applied: Finally, the change in magnetic flux is divided by the time interval and multiplied by the number of turns of the coil N, you get the induced electromotive force.


  • Direction judgment: According to Lenz's law, the direction of the induced electromotive force always causes the current generated by it to produce a magnetic field, which will hinder the change of the original magnetic field. That is, the direction of the induced electromotive force always tries to counteract the change in magnetic flux that causes it.


58a3ab58ca3e4ddb31d9ca1997f1933d.jpeg


Give a tip and encourage the author!
Recommended
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
Edwiin
08/28/2025
Leading vs Lagging Power Factor | Phase Difference Explained
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
Edwiin
08/26/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.