Capacitive Current Estimation for Overhead and Cable Power Lines

Leon
Leon
Field: Fault Diagnosis
China

The capacitive current is mainly determined by the length of the feeder, the cross-sectional area of the conductor, the dielectric constant, the height above the ground, and the rated voltage. The specific estimation methods are as follows:

  • Estimation of capacitive current of overhead lines: For overhead lines of 3 - 35 kV, the capacitance per phase to ground is usually 5000 - 6000 pF/km. Based on this, the value of the single-phase grounding capacitive current per kilometer for lines of different voltage levels can be estimated.

  • Estimation of capacitive current of cable lines: The capacitive current of cable lines is much larger than that of overhead lines and needs to be calculated separately. Its value is closely related to the cross-sectional area, structure, and rated voltage of the cable.

  • Estimation of capacitive current of double-circuit overhead lines on the same pole: The capacitive current of such lines is not twice that of a single-circuit line. When equivalently calculated as a single-circuit line, the formula is: Ic = (1.4 - 1.6)Id (where Id is the capacitive current corresponding to the length of a single circuit in the double-circuit lines). The constant values need to be distinguished by voltage level: 1.4 corresponds to 10 kV lines, and 1.6 corresponds to 35 kV lines.

Give a tip and encourage the author!
Recommended
Standards and Calculation of LTAC Test for Power Transformers
Standards and Calculation of LTAC Test for Power Transformers
1 IntroductionAccording to the provisions of the national standard GB/T 1094.3-2017, the primary purpose of the line terminal AC withstand voltage test (LTAC) for power transformers is to evaluate the AC dielectric strength from the high-voltage winding terminals to ground. It does not serve to assess inter-turn insulation or phase-to-phase insulation.Compared with other insulation tests (such as full lightning impulse LI or switching impulse SI), the LTAC test imposes a relatively more stringen
Oliver Watts
11/03/2025
Complete Guide to Circuit Breaker Selection and Setting Calculation
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
Echo
10/28/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
How to Correctly Calculate SST Transformer kVA Capacity?
How to Correctly Calculate SST Transformer kVA Capacity?
ransformer Capacity Selection: Ensuring Reliable and Efficient Power System OperationTransformer capacity refers to the apparent power at the transformer’s main tap position. The value indicated on the nameplate is known as the rated capacity, typically expressed in kilovolt-amperes (kVA). In practical operation, improperly sized transformers can lead to either under-loading (due to oversizing) or overloading/overcurrent conditions, which may result in equipment overheating, reduced efficiency,
Edwiin
10/27/2025