Cause of squirrel cage motor creepage

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Creepage in squirrel cage motors refers to the phenomenon where the rotor begins to rotate even though the motor is not receiving sufficient voltage to fully start or maintain rotation. This can happen under certain conditions, particularly when there is residual magnetism or when the motor is subjected to external forces that cause it to turn slightly. Here are the main causes of creepage in squirrel cage motors:


Residual Magnetism


  • Magnetic Fields: Even after the power supply is cut off, some residual magnetic fields may remain in the stator windings or other magnetic components of the motor. These fields can induce a small current in the rotor bars, causing slight rotation.


  • Permanent Magnets: Some motors incorporate permanent magnets in their design, which can contribute to creepage if they are strong enough to induce currents in the rotor.


External Forces


  • Mechanical Loads: If the motor is connected to a mechanical load that applies a slight rotational force, it may cause the rotor to creep. For example, gravity acting on a vertically oriented pump shaft might cause the motor to turn slightly.



  • Wind or Vibrations: External forces such as wind or vibrations from nearby equipment can impart a small rotational movement to the motor.


Design Characteristics


  • Rotor Imbalance: If the rotor is not perfectly balanced, it may exhibit slight movements due to unbalanced forces acting on it.



  • Motor Design: Certain designs of squirrel cage motors might be more prone to creepage due to their construction details.


Electrical Phenomena


  • Stray Capacitance: Stray capacitance between the stator and rotor can sometimes cause a small current to flow, inducing slight rotation.



  • Partial Discharge: Partial discharge in the insulation of the motor can generate small currents that lead to creepage.


Faulty Electrical Connections


  • Loose Connections: Loose connections in the wiring or terminals can create intermittent paths for current flow, leading to creepage.



  • Faulty Controls: Faulty relays or contactors that do not completely break the circuit can allow a small current to pass through the motor, causing slight rotation.


Mitigation Strategies


To reduce or eliminate creepage in squirrel cage motors, several strategies can be employed:


  • Ensure Proper Load Management: Properly manage the mechanical loads attached to the motor to prevent unnecessary forces from acting on the rotor.



  • Balancing: Balance the rotor to minimize any unbalanced forces that could cause rotation.



  • Shielding: Shield the motor from external forces and vibrations that might contribute to creepage.



  • Maintenance: Regularly check and tighten all electrical connections and ensure that all components are functioning correctly.



  • Design Improvements: Incorporate design improvements that minimize residual magnetic fields and enhance the overall stability of the motor.


Summary


Creepage in squirrel cage motors is caused by residual magnetism, external forces, design characteristics, electrical phenomena, and faulty electrical connections. By understanding these causes and implementing appropriate mitigation strategies, one can effectively reduce or prevent creepage in motor operation.


Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
The use of power electronics in industry is increasing, ranging from small-scale applications such as chargers for batteries and LED drivers, to large-scale applications like photovoltaic (PV) systems and electric vehicles. Typically, a power system consists of three parts: power plants, transmission systems, and distribution systems. Traditionally, low-frequency transformers are used for two purposes: electrical isolation and voltage matching. However, 50-/60-Hz transformers are bulky and heavy
Dyson
10/27/2025
SST vs Traditional Transformer: Key Advantages
SST vs Traditional Transformer: Key Advantages
Solid-State Transformers (SST): The Future of Intelligent Power ConversionA solid-state transformer (SST), also known as a power electronic transformer (PET), is a static power conversion device that integrates power electronics, high-frequency transformation, and advanced control systems based on electromagnetic induction. It enables the conversion of electrical energy from one set of voltage, current, and frequency characteristics to another—while offering active control, bidirectional power f
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.