What is an Over Current Relay?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is an Over Current Relay?


Overcurrent Relay Definition


An overcurrent relay is a protective device that operates solely based on current without the need for a voltage coil.


Working Principle of Over Current Relay


The core component of an overcurrent relay is a current coil. Under normal conditions, the coil’s magnetic effect is too weak to overcome the restraining force and move the relay’s element. However, if the current increases sufficiently, its magnetic effect intensifies, surpassing the restraining force and prompting the moving element to alter the relay’s contact position. This fundamental working principle applies across different types of overcurrent relays.


Types of Over Current Relay


Depending upon time of operation, there are various types of Over Current relays, such as,

 


  • Instantaneous over current relay.

  • Definite time over current relay.

  • Inverse time over current relay.

 


Inverse time over current relay or simply inverse OC relay is again subdivided as inverse definite minimum time (IDMT), very inverse time, extremely inverse time over current relay or OC relay.


Instantaneous Over Current Relay


Construction and working principle of instantaneous over current relay is quite simple.In an instantaneous overcurrent relay, a magnetic core is wrapped with a current coil. An iron piece, supported by a hinge and a restraining spring, is positioned such that it remains detached from the core when current is below a preset threshold, keeping the normally open (NO) contacts open. Exceeding this threshold, the increased magnetic attraction pulls the iron to the core, closing the contacts.


We refer the pre-set value of current in the relay coil as pickup setting current. This relay is referred as instantaneous over current relay, as ideally, the relay operates as soon as the current in the coil gets higher than pick upsetting current. There is no intentional time delay applied. But there is always an inherent time delay which we cannot avoid practically. In practice, the operating time of an instantaneous relay is of the order of a few milliseconds.


b58d1e2d9d52b157b1e62dc1744a6168.jpeg

eef838fb4bb68cf33435835ad763ca68.jpeg


Definite Time Over Current Relay


This relay is created by applying intentional time delay after crossing pick up the value of the current. A definite time overcurrent relay can be adjusted to issue a trip output at an exact amount of time after it picks up. Thus, it has a time setting adjustment and pickup adjustment.


a97bfb0676289b6070e9f9b887f6ef49.jpeg


Inverse Time Over Current Relay


Inverse time overcurrent relays, typically found in induction type rotating devices, operate faster with increased input current, inversely varying their operation time with current. This characteristic is ideal for swift fault clearing in severe conditions. Additionally, this inverse timing can also be programmed into microprocessor-based relays, enhancing their versatility in overcurrent protection.


4807ad3835da85c436539992efded118.jpeg


Inverse Definite Minimum Time Over Current Relay or IDMT O/C Relay


In an overcurrent relay, achieving perfect inverse time characteristics is challenging. As system current rises, so does the secondary current from the current transformer (CT) until the CT saturates, halting further increases in relay current. This saturation marks the limit of inverse characteristic effectiveness, leading to a fixed minimum operation time despite further increases in fault level. This behavior defines the IDMT relay, noted for its inverse response initially, which stabilizes at high current levels.

 

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
Transformer Longitudinal Differential Protection: Common Issues and SolutionsTransformer longitudinal differential protection is the most complex among all component differential protections. Misoperations occasionally occur during operation. According to 1997 statistics from the North China Power Grid for transformers rated 220 kV and above, there were 18 incorrect operations in total, of which 5 were due to longitudinal differential protection—accounting for approximately one-third. Causes of
Felix Spark
11/05/2025
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
What Are the Factors Influencing the Impact of Lightning on 10kV Distribution Lines?
1. Induced Lightning OvervoltageInduced lightning overvoltage refers to the transient overvoltage generated on overhead distribution lines due to nearby lightning discharges, even when the line is not directly struck. When a lightning flash occurs in the vicinity, it induces a large amount of charge on the conductors—opposite in polarity to the charge in the thundercloud.Statistical data shows that lightning-related faults caused by induced overvoltages account for approximately 90% of total fau
Echo
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.