Protection measures for use of three-phase transformers


Three-phase transformer may encounter various faults and abnormal working conditions during use, in order to ensure its safe and stable operation, a series of protective measures are usually taken. The following are several common protection measures for three-phase transformers according to the search results:


Gas protection


Gas protection is a protective measure used to reflect the internal failure of the transformer tank and the reduction of the oil level. When the fault in the tank produces slight gas or the oil level drops, the gas protection should be activated at the signal; When a large amount of gas is generated, the circuit breaker on each side of the transformer should be disconnected.


Longitudinal differential protection or current velocity break protection


This protection measure is used to reflect the short-circuit between the transformer winding and the lead line, and the single-phase grounding short-circuit between the neutral point direct grounding system winding and the lead line. It can quickly detect the fault and activate the protection mechanism, cut off the power and avoid the expansion of the fault.


Overcurrent protection


Overcurrent protection is used to reflect the external phase short circuit of the transformer, and as a backup protection for gas protection and differential protection (or current current break protection). This protection can be used as the last line of defense when the gas protection and differential protection fail, cutting off the power supply and protecting the transformer from damage.


Zero sequence current protection


Zero sequence current protection is used to protect the external single-phase grounding short circuit of the system with high grounding current. It detects the presence of zero sequence current and initiates protective action to avoid transformer damage due to ground failure.


Overload protection


Overload protection is used to reflect the symmetric overload of the transformer. This protection only acts on the signal and does not immediately cut off the power supply, but warns the staff that the transformer is overloaded and needs to be adjusted.


Overexcitation protection


Overexcitation protection is used to prevent transformer damage due to overexcitation. When the overexcitation of the transformer exceeds the allowable limit, the overexcitation protection will be activated, sending a signal or acting on the trip, limiting the degree of overexcitation.


Differential protection


Differential protection is an important protection measure, which can reflect the fault of transformer outlet line, bushing and internal short circuit. This kind of protection can be operated instantaneously on each side of the transformer circuit breaker, which is of great significance for the protection of transformer equipment.


Neutral point direct grounding protection


For the transformer directly grounded at the neutral point, when the single phase grounding fault occurs, it will produce a large short circuit current. The ground protection device determines whether the ground fault occurs by detecting the zero sequence current, and acts to remove the fault part in time.


Neutral point is not grounded or protected by arc suppression coil


For the transformer with ungrounded neutral or grounded by arc suppression coil, when the single-phase grounding fault occurs, the grounding current is small, and the zero-sequence voltage protection or insulation monitoring device is usually used to detect the grounding fault.


Temperature protection


The transformer will generate heat during operation, and when the temperature is too high, the insulation performance and service life of the transformer will be affected. The purpose of temperature protection is to monitor the temperature change of the transformer, and when the temperature exceeds the set value, send an alarm signal or act on the trip to prevent the transformer from overheating and damage.


Give a tip and encourage the author!
Recommended
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
When installing an arc suppression coil, it is important to identify the conditions under which the coil should be taken out of service. The arc suppression coil should be disconnected under the following circumstances: When a transformer is being de-energized, the neutral-point disconnector must be opened first before performing any switching operations on the transformer. The energizing sequence is the reverse: the neutral-point disconnector should be closed only after the transformer is energ
Echo
11/05/2025
What fire prevention measures are available for power transformer failures?
What fire prevention measures are available for power transformer failures?
Failures in power transformers are commonly caused by severe overload operation, short circuits due to winding insulation degradation, aging of transformer oil, excessive contact resistance at connections or tap changers, failure of high- or low-voltage fuses to operate during external short circuits, core damage, internal arcing in oil, and lightning strikes.Since transformers are filled with insulating oil, fires can have severe consequences—ranging from oil spraying and ignition to, in extrem
Noah
11/05/2025
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
Transformer Longitudinal Differential Protection: Common Issues and SolutionsTransformer longitudinal differential protection is the most complex among all component differential protections. Misoperations occasionally occur during operation. According to 1997 statistics from the North China Power Grid for transformers rated 220 kV and above, there were 18 incorrect operations in total, of which 5 were due to longitudinal differential protection—accounting for approximately one-third. Causes of
Felix Spark
11/05/2025
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.