Failure Analysis of Electric Vehicle AC Charging Piles

Felix Spark
Felix Spark
Field: Failure and maintenance
China

As new energy electric vehicles become increasingly popular, the number of supporting public charging piles is growing year by year. Whether the measurement value of AC charging piles for electric vehicles is accurate is directly related to the vital interests of the vast number of electric vehicle owners. So, conducting regular mandatory inspections of charging piles is particularly important. Below, combined with relevant regulations and practical work, I’ll share some experience and practices on properly carrying out verification, fault analysis, repair, and correct maintenance of AC charging piles for electric vehicles.

1 Common Faults of AC Charging Piles for Electric Vehicles

During the use of AC charging piles, the main circuit is directly affected by current and voltage stress, which is the main cause of faults in AC charging piles. In terms of fault states, there are mainly two common situations for charging piles.

1.1 The power indicator of the charging pile is not on and it can’t charge
1.1.1 Fault Causes

A possible fault cause is that the charging power connection is abnormal:

The AC charging connection device is not properly connected; there is a fault in the charging pile circuit.

1.1.2 Fault Diagnosis & Troubleshooting

Diagnosis flow as Figure 1.

  • Check distribution cabinet main switch (closed in normal operation; close if open).

  • Test main switch output voltage (L - N, L - PE should be 220V). Abnormal voltage → check/reconnect circuit or replace switch (open, loose, damaged).

  • Test charging pile input voltage (L - N, L - PE should be 220V). Abnormal voltage → reconnect circuit or replace switch (open/damaged).

1.2 Physical Connection Done, Charging Started but No Charge

Occurs when power, plug - battery connection, and standby state are normal. 7 cases:

  • Normal charge but monitoring data shows 0 → Communication fault between pile & system.
    Fix: ① Restart monitoring/server; ② Reboot pile display; ③ Power - cycle display system & program.

  • Charge current <20A (normal state) &rarr; Display/program fault.
    Fix: ① Restart display program; ② Power - cycle pile & program; ③ Reinstall display/program.

  • Can&rsquo;t charge/enter interface &rarr; Communication fault.
    Fix: ① Check display parameters; ② Power - cycle display system/program; ③ Reinstall display/program.

  • No BMS communication after display reboot &rarr; Communication fault.
    Fix: ① Power - cycle display system/program; ② Reinstall display/program; ③ Replace CAN bus module 200T.

  • BMS normal, voltage normal but 0 current &rarr; Mistaken emergency stop press.
    Fix: ① Release emergency stop; ② Check battery & BMS.

  • BMS normal, no charge voltage &rarr; Mistaken emergency stop press.
    Fix: ① Release emergency stop; ② Check battery & BMS.

  • BMS normal, voltage fluctuates, 0 current &rarr; Charging module fault.
    Fix: Replace module.

2 Proper Use & Maintenance of EV Charging Piles

  • Pre - charge: Inspect equipment (cables, connectors) for damage.

  • Abnormality during use: Press emergency stop &rarr; cut all power.

  • Keep flammables/explosives (gases, chemicals) away.

  • Don&rsquo;t use if gun/cable has defects (cracks, wear, exposed wires).

  • Never unplug during charging; no live - contact with gun core.

  • Avoid outdoor charging in rain/thunder. Prohibit charging if water nears vehicle height.

Give a tip and encourage the author!
Recommended
Hydraulic Leak & SF6 Gas Leakage in Circuit Breakers
Hydraulic Leak & SF6 Gas Leakage in Circuit Breakers
Leakage in Hydraulic Operating MechanismsFor hydraulic mechanisms, leakage can cause short-term frequent pump starting or excessively long re-pressurization time. Severe internal oil seepage in valves may lead to pressure loss failure. If hydraulic oil enters the nitrogen side of the accumulator cylinder, it can cause abnormal pressure rise, which affects the safe operation of SF6 circuit breakers.Apart from failures caused by damaged or abnormal pressure detection devices and pressure component
Felix Spark
10/25/2025
10kV RMU Common Faults & Solutions Guide
10kV RMU Common Faults & Solutions Guide
1.Application Issues and Handling Measures for 10kV Ring Main Units (RMUs)The 10kV ring main unit (RMU) is a core power distribution device in urban 10kV distribution networks, widely used in industrial parks, residential communities, commercial centers, and public facilities for medium-voltage power supply and flexible power distribution. Its primary function is to enable flexible energy distribution, ring-fed operation, and fault isolation at the 10kV voltage level. However, during long-term o
Echo
10/20/2025
HV Breaker Fault Basics: Training Guide for New Engineers
HV Breaker Fault Basics: Training Guide for New Engineers
High-Voltage Circuit Breakers: Classification and Fault DiagnosisHigh-voltage circuit breakers are critical protective devices in power systems. They rapidly interrupt current when a fault occurs, preventing damage to equipment from overloads or short circuits. However, due to long-term operation and other factors, circuit breakers may develop faults that require timely diagnosis and troubleshooting.I. Classification of High-Voltage Circuit Breakers1. By Installation Location: Indoor-type: Insta
Felix Spark
10/20/2025
10 Prohibitions for Transformer Installation and Operation!
10 Prohibitions for Transformer Installation and Operation!
10 Prohibitions for Transformer Installation and Operation! Never install the transformer too far away—avoid placing it in remote mountains or wilderness. Excessive distance not only wastes cables and increases line losses, but also makes management and maintenance difficult. Never choose transformer capacity arbitrarily. Selecting the right capacity is essential. If the capacity is too small, the transformer may be overloaded and easily damaged—overloading beyond 30% should not exceed two hours
James
10/20/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.