DC Generators Performance Curves

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Performance Curves Definition

Performance curves of a DC generator are graphs that show how the output voltage changes as the load current varies from no load to full load. These are also known as characteristic curves. These curves help us understand the voltage regulation of different types of DC generators. Better performance is indicated by lower voltage regulation.

Separately Excited DC Generator

Though this type of DC generators are rarely used due to its cost for the separate excitation but the performance of these DC generators are quite satisfactory. In separately excited DC generators, the terminal voltage as the load increases and the load current started to flow.

There is slight drop in the terminal voltage due to armature reaction and IR drop but these drop can be eliminated by increasing field excitation and then we can get constant terminal voltage. In the diagram below, the curve AB is showing this characteristic.

Series Wound DC Generator

In series DC generators, the terminal voltage at no load is zero because no current flows through the field winding. As the load increases, the output voltage rises. The terminal voltage varies widely with small changes in load current. Due to armature reaction and ohmic drop in the armature winding, the output voltage is lower than the generated voltage.

Shunt Wound DC Generator

In shunt wound DC generators, there is always some voltage at no load due to the shunt field winding. As the load increases, the terminal voltage drops quickly because of strong demagnetizing armature reaction and resistance drop. This drastic reduction in terminal voltage leads to a decrease in load current, resulting in poor performance of this type of generators.

Compound Wound DC Generator

At no load, the performance curve of this type of DC generator is same as that of shunt field generators because at no load, there is no current in the series field winding. When the load increases, then the terminal voltage drops due to the shunt DC generator, but the voltage rise in the series DC generator compensates the voltage drop. For these reason the terminal voltage remains constant. The terminal voltage can also make higher or lower by controlling the amp-turns of the series field winding. In the diagram below, the curve FG is showing this characteristic.

a08420d0433e6d6f7a185f2e38d71b7d.jpeg


Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
The use of power electronics in industry is increasing, ranging from small-scale applications such as chargers for batteries and LED drivers, to large-scale applications like photovoltaic (PV) systems and electric vehicles. Typically, a power system consists of three parts: power plants, transmission systems, and distribution systems. Traditionally, low-frequency transformers are used for two purposes: electrical isolation and voltage matching. However, 50-/60-Hz transformers are bulky and heavy
Dyson
10/27/2025
SST vs Traditional Transformer: Key Advantages
SST vs Traditional Transformer: Key Advantages
Solid-State Transformers (SST): The Future of Intelligent Power ConversionA solid-state transformer (SST), also known as a power electronic transformer (PET), is a static power conversion device that integrates power electronics, high-frequency transformation, and advanced control systems based on electromagnetic induction. It enables the conversion of electrical energy from one set of voltage, current, and frequency characteristics to another—while offering active control, bidirectional power f
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.