What is the Parallel Operation of DC Generators?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

What is the Parallel Operation of DC Generators?

Parallel operation definition of DC generator

In modern power systems, power is usually provided by many parallel synchronous generators to ensure continuous operation of the plant. The use of single large generators is now obsolete. Having two generators in parallel helps keep them in sync. Adjusting their armature currents and properly connecting them to the bus bars can solve any synchronization problems.

Busbar connection

Generators in power plants are connected by thick copper bars, called busbars, that act as positive and negative electrodes. To parallel the generator, connect the positive terminal of the generator to the positive terminal of the bus, and the negative terminal of the generator to the negative terminal of the bus, as shown in the figure.

To connect the second generator to the existing generator, first increase the speed of the prime mover of the second generator to the rated speed. Then, close switch S4.

Circuit breaker V2 (voltmeter) is connected to the open switch S 2 close to complete the circuit. The excitation of generator 2 is increased with the help of a field rheostat until it produces a voltage equal to the bus voltage.

Next, turn off the main switch S2 to connect the second generator in parallel with the existing generator. At this point, generator 2 is not yet powered because its induced electromotive force is equal to the bus voltage. This state is called "floating," which means the generator is ready but not providing current.

In order to supply current from generator 2, its induced e.m.f. E must be greater than the bus voltage V. By strengthening the excitation current, the induced electromotive force of generator 2 can be increased and the supply current can be started. In order to maintain the bus voltage, the magnetic field of generator 1 is weakened so that the value remains constant.

The field current I is given by Where, R786715bccdb1f10821bef3c6af44e0f3.jpeg


b6f2dec2a3e26264fb418a323d48f1e6.jpeg

Load distribution

By adjusting the induced electromotive force, the load is transferred to another generator, but in modern power plants everything is done by the "sychroscope", which gives instructions to the governor of the prime mover. Let's assume that the two generators have different load voltages. Then the load distribution between these generators will be the value of the current output depending on the value of E 1 and E3 which can be managed by a field rheostat to keep the bus voltage constant.

6834c43b1adc011cbae18a4631f44ffe.jpeg

Advantage

Smooth power supply: If the generator fails, the power supply will not be interrupted. If one generator fails, the other healthy generator sets can continue to maintain continuity of power.

Easy maintenance:Routine maintenance of the generator is needed from time to time. But for that, the power supply must not be impeded. In parallel generators, routine checks can be carried out one by one.

Easy to increase factory capacity: Electricity demand is increasing. To meet the needs of power generation, additional new units can be operated in parallel with operating units.

Matters needing attention

  • The specifications of each generator are different. When they are synchronized together, their speed is locked into the overall speed of the system.

  • The full load of the system should be distributed among all the generators.

  • There should be a controller to check the engine's parameters. This can be done with modern digital controllers available on the market.

  • Voltage regulation plays an important role in the whole system. If the voltage of one unit drops, it ends up bearing the entire voltage load of the shunt generator system compared to the other units.

  • Extra precautions should be taken when connecting terminals to bus bars. If the generator is connected to the wrong rod polarity, it may cause a short circuit.

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
The use of power electronics in industry is increasing, ranging from small-scale applications such as chargers for batteries and LED drivers, to large-scale applications like photovoltaic (PV) systems and electric vehicles. Typically, a power system consists of three parts: power plants, transmission systems, and distribution systems. Traditionally, low-frequency transformers are used for two purposes: electrical isolation and voltage matching. However, 50-/60-Hz transformers are bulky and heavy
Dyson
10/27/2025
SST vs Traditional Transformer: Key Advantages
SST vs Traditional Transformer: Key Advantages
Solid-State Transformers (SST): The Future of Intelligent Power ConversionA solid-state transformer (SST), also known as a power electronic transformer (PET), is a static power conversion device that integrates power electronics, high-frequency transformation, and advanced control systems based on electromagnetic induction. It enables the conversion of electrical energy from one set of voltage, current, and frequency characteristics to another—while offering active control, bidirectional power f
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.