Sometimes an AC 3-phase motor star connection below 4kW. Why?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

The reason for using a star connection for three-phase AC motors below 4 kW.

AC three-phase motors below 4kW typically use a star (Y) connection due to several advantages it offers:

  1. Reduce the voltage on the windings: In star connection, each phase winding is subjected to a voltage that is 1/√3 of the line voltage, i.e., 220V instead of 380V. This helps to reduce the voltage on the windings, thereby lowering the insulation level requirements.

  2. Reduce Starting Current: Star connection significantly reduces starting current, which is beneficial for protecting the motor and electrical equipment from excessive impact currents. Lower starting current also helps extend the motor's lifespan.

  3. Suitable for small power motors: Due to the star connection's ability to effectively reduce power, it is particularly suitable for use in small power motors. Motors below 4 kW usually do not require high power output, making the star connection a suitable choice.

Differences between star connection and delta connection

  • Power Size: For motors with delta connection, star-delta starting is used for light load starting to reduce the starting current. Light load is a condition because the torque will be smaller with star connection, and reducing the starting current is the purpose by using star connection to lower the starting current. Delta connection has high power and large starting current, while star connection has low power and small starting current.

  • Pros and Cons:

  • Delta Connection: This method helps to increase motor power, but the disadvantage is that it has a large starting current and the winding withstands a high voltage (380V).

  • Star Connection: This helps to reduce the voltage (220V) on the winding, lowering the insulation grade and decreasing the starting current. However, the drawback is that it reduces the motor power.

Conclusion

In summary, the star connection for three-phase AC motors below 4 kW is mainly used to reduce the voltage and starting current borne by the winding, while adapting to their low power requirements. This connection method helps protect the motor and electrical equipment and extend the service life of the motor.

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
Design of a Four-Port Solid-State Transformer: Efficient Integration Solution for Microgrids
The use of power electronics in industry is increasing, ranging from small-scale applications such as chargers for batteries and LED drivers, to large-scale applications like photovoltaic (PV) systems and electric vehicles. Typically, a power system consists of three parts: power plants, transmission systems, and distribution systems. Traditionally, low-frequency transformers are used for two purposes: electrical isolation and voltage matching. However, 50-/60-Hz transformers are bulky and heavy
Dyson
10/27/2025
SST vs Traditional Transformer: Key Advantages
SST vs Traditional Transformer: Key Advantages
Solid-State Transformers (SST): The Future of Intelligent Power ConversionA solid-state transformer (SST), also known as a power electronic transformer (PET), is a static power conversion device that integrates power electronics, high-frequency transformation, and advanced control systems based on electromagnetic induction. It enables the conversion of electrical energy from one set of voltage, current, and frequency characteristics to another—while offering active control, bidirectional power f