• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Maximum Torque Condition of an Induction Motor

Edwiin
Edwiin
Field: Power switch
China

In the article titled "Torque Equation of an Induction Motor", we've already examined the developed torque and its corresponding equation. Now, we'll discuss the Maximum Torque Condition of an induction motor. The torque generated in an induction motor mainly hinges on three factors: the magnitude of the rotor current, the interaction between the rotor and the magnetic flux of the motor, and the rotor's power factor. The equation for the torque value during the motor's operation is as follows:

The phase angle of the total impedance of the RC network always ranges from 0º to 90º. Impedance represents the opposition that an electronic circuit element presents to the flow of current. When the impedance of the stator winding is considered negligible, for a given supply voltage V1, E20 remains constant.

The developed torque will reach its maximum value when the right - hand side of Equation (4) is maximized. This occurs when the value of the denominator, as shown below, is equal to zero.

Let,

Thus, the developed torque attains its maximum value when the rotor resistance per phase equals the rotor reactance per phase under running conditions. Substituting sX20 = R2 into Equation (1) yields the expression for the maximum torque.

The above equation indicates that the magnitude of the maximum torque is independent of rotor resistance.

If  denotes the slip value corresponding to the maximum torque, then from Equation (5):

Therefore, the rotor speed at the point of maximum torque is given by the equation below:

The following conclusions regarding the maximum torque can be derived from Equation (7):

  • Independence from Rotor Resistance: The magnitude of the maximum torque is independent of the rotor circuit resistance.

  • Inverse Proportionality to Rotor Reactance: The maximum torque varies inversely with the standstill reactance X20 of the rotor. Thus, to maximize torque, X20 (and consequently, the rotor inductance) should be minimized.

  • Adjustability via Rotor Resistance: By adjusting the resistance in the rotor circuit, maximum torque can be achieved at any target slip or speed. This is determined by the rotor resistance at the slip sM = R2/X20.

  • Rotor Resistance Requirement for Different Conditions:

    • To achieve maximum torque at standstill, the rotor resistance must be high and equal to X20.

    • For maximum torque under running conditions, the rotor resistance should be low.

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
Rectifier vs Power Transformer: Key Differences
Rectifier vs Power Transformer: Key Differences
Differences Between Rectifier Transformers and Power TransformersRectifier transformers and power transformers both belong to the transformer family, but they differ fundamentally in application and functional characteristics. The transformers commonly seen on utility poles are typically power transformers, while those supplying electrolytic cells or electroplating equipment in factories are usually rectifier transformers. Understanding their differences requires examining three aspects: working
Echo
10/27/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Upgrade Traditional Transformers: Amorphous or Solid-State?
Upgrade Traditional Transformers: Amorphous or Solid-State?
I. Core Innovation: A Dual Revolution in Materials and StructureTwo key innovations:Material Innovation: Amorphous AlloyWhat it is: A metallic material formed by ultra-rapid solidification, featuring a disordered, non-crystalline atomic structure.Key Advantage: Extremely low core loss (no-load loss), which is 60%–80% lower than that of traditional silicon steel transformers.Why it matters: No-load loss occurs continuously, 24/7, throughout a transformer’s lifecycle. For transformers with low loa
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.