Slip Speed in an Induction Motor

Edwiin
Edwiin
Field: Power switch
China

Slip Speed in an Induction Motor

Definition: The slip of an induction motor is defined as the difference between the synchronous speed of the main magnetic flux and the rotor speed. Denoted by the symbol S, it is expressed as a percentage of the synchronous speed. Mathematically, it is formulated as:

This revision enhances technical precision by clarifying "main flux speed" as the synchronous speed (a standard term in electrical engineering), and structures the definition to align with academic notation. The use of S as a standardized symbol and the explicit mention of "percentage" improves clarity for readers.

The slip value at full load typically ranges from 6% for small motors to 2% for large motors.

An induction motor never operates at synchronous speed; the rotor speed always remains lower than the synchronous speed. If the rotor speed were equal to the synchronous speed, there would be no relative motion between the stationary rotor conductors and the main magnetic field. Consequently, no electromotive force (EMF) would be induced in the rotor, leading to zero current in the rotor conductors and no electromagnetic torque. For this reason, the rotor speed is always maintained slightly below the synchronous speed. The speed at which the induction motor functions is referred to as the slip speed.

The slip speed is defined as the difference between the synchronous speed and the actual rotor speed. In other words, it represents the relative speed of the rotor with respect to the magnetic field speed. Since the rotor speed is slightly less than the synchronous speed, the slip speed quantifies the rotor's speed relative to the field.

  • Let Ns be the synchronous speed (in revolutions per minute, rpm).

  • Let Nr be the actual rotor speed (in rpm).

The slip speed of the induction motor is given by:

The fractional ratio of the synchronous speed is termed the per-unit slip or fractional slip, commonly referred to simply as the "slip" and denoted by the symbol s.

Therefore, the rotor speed is given by the equation shown below:

Alternatively, if:

  • ns is the synchronous speed (in revolutions per second, rps),

  • nr is the actual rotor speed (in rps),

The percentage slip in revolution per second is given as shown below.

The slip of an induction motor typically ranges from 5% for small motors to 2% for large motors.

Importance of Slip

Slip is fundamental to the operation of an induction motor. As established, slip speed is defined as the difference between the synchronous speed and the rotor speed. This relative motion—i.e., the slip speed—drives the induction of electromotive force (EMF) in the rotor. Specifically:

he rotor current is directly proportional to the induced emf.

he torque is directly proportional to the rotor current.

 

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
Rectifier vs Power Transformer: Key Differences
Rectifier vs Power Transformer: Key Differences
Differences Between Rectifier Transformers and Power TransformersRectifier transformers and power transformers both belong to the transformer family, but they differ fundamentally in application and functional characteristics. The transformers commonly seen on utility poles are typically power transformers, while those supplying electrolytic cells or electroplating equipment in factories are usually rectifier transformers. Understanding their differences requires examining three aspects: working
Echo
10/27/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Upgrade Traditional Transformers: Amorphous or Solid-State?
Upgrade Traditional Transformers: Amorphous or Solid-State?
I. Core Innovation: A Dual Revolution in Materials and StructureTwo key innovations:Material Innovation: Amorphous AlloyWhat it is: A metallic material formed by ultra-rapid solidification, featuring a disordered, non-crystalline atomic structure.Key Advantage: Extremely low core loss (no-load loss), which is 60%–80% lower than that of traditional silicon steel transformers.Why it matters: No-load loss occurs continuously, 24/7, throughout a transformer’s lifecycle. For transformers with low loa
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.