What is the reason for not using two windings at far distances in transformers?

Encyclopedia
11/09/2024

In transformer design, it is typically not advisable to use widely separated windings (i.e., primary and secondary windings with a significant physical distance between them). Here are the main reasons for avoiding widely separated windings:

1. Reduced Magnetic Coupling Efficiency

Magnetic Coupling: Transformers work on the principle of electromagnetic induction, where alternating current in the primary winding generates an alternating magnetic field, which induces a voltage in the secondary winding. If the distance between the primary and secondary windings is large, the magnetic field strength will significantly weaken, leading to poor magnetic coupling efficiency.

Leakage Flux: Widely separated windings result in more leakage flux, which is the portion of the magnetic field that fails to couple effectively with the secondary winding and instead dissipates into the surrounding environment, reducing the transformer's efficiency.

2. Increased Parasitic Capacitance

Parasitic Capacitance: When the distance between windings increases, the parasitic capacitance between the windings also increases. Parasitic capacitance creates unwanted current paths at high frequencies, leading to energy losses and interference.

Frequency Response: Parasitic capacitance affects the frequency response of the transformer, particularly in high-frequency applications, where increased parasitic capacitance can cause signal attenuation and distortion.

3. Increased Manufacturing Difficulty and Cost

Manufacturing Difficulty: Widely separated windings require more complex manufacturing processes, increasing production difficulty and cost.

Material Usage: Widely separated windings necessitate more insulating materials and support structures, increasing material costs and weight.

4. Increased Size and Weight

Size and Weight: Widely separated windings increase the overall size and weight of the transformer, making it less suitable for miniaturization and lightweight design.

Installation Space: Larger size and weight limit the installation space for the transformer, especially in compact devices.

5. Thermal Management Issues

Thermal Management: Widely separated windings can lead to uneven heat distribution, increasing the difficulty of thermal management. Localized overheating can affect the performance and lifespan of the transformer.

Cooling: Closely packed windings are easier to cool effectively using heat sinks or other cooling mechanisms.

6. Electromagnetic Interference

Electromagnetic Interference (EMI): Widely separated windings may generate stronger electromagnetic interference (EMI), affecting the proper operation of nearby electronic devices.

Shielding: Additional shielding measures may be required to reduce EMI, further increasing cost and complexity.

Summary

In transformer design, avoiding widely separated windings is essential to improve magnetic coupling efficiency, reduce leakage flux and parasitic capacitance, lower manufacturing difficulty and cost, minimize size and weight, enhance thermal management, and reduce electromagnetic interference. These factors collectively ensure the efficiency, reliability, and cost-effectiveness of the transformer. 

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!