Methods to Reduce Core Loss in Transformers

The iron core loss in transformers mainly includes hysteresis loss and eddy current loss. Here are some effective methods to reduce these losses:

1. Choose high-quality iron core materials

  • High Permeability Materials: Using high permeability and low loss silicon steel sheets as transformer core materials can effectively reduce hysteresis loss and eddy current loss.

  • Low Loss Material: Choose low loss silicon steel sheets with smaller grains and higher resistance, which have weaker conductivity of magnetic flux in the silicon steel sheet, thus achieving the purpose of reducing eddy current losses.

2. Optimize the core structure

  • Stacked Structure: A stacked structure for the magnetic core can reduce the loss of magnetic flux. Properly designing the air gap and cross-sectional area of the magnetic core structure can also minimize the iron loss in the transformer.

  • Rational Design: The design of the iron core structure should be reasonable to ensure that the magnetic flux path is short and thick, reducing the length and resistance of the magnetic flux path, thereby lowering the iron loss.

3. Reduce Magnetic Flux Density

  • Flux Density Control: Excessive flux density can lead to increased eddy current losses and core losses. Therefore, when designing and manufacturing transformers, it is necessary to select the appropriate flux density based on specific operating conditions and requirements, minimizing the flux density as much as possible to reduce iron losses.

  • Balanced Trade-offs: Reducing the magnetic flux density can decrease the iron losses in a transformer, but it also increases the size and weight of the transformer. Therefore, a balanced trade-off for the magnetic flux density needs to be made during the design process.

4. Choose low-loss insulating materials

  • Insulation Material: Properly selecting low-loss insulation materials can reduce the overall loss of transformers.

  • Winding Insulation: Proper insulation of the winding to prevent eddy current loss due to electromagnetic induction.

5. Optimize Manufacturing Processes

  • Precise Manufacturing: The adoption of precision wet iron core manufacturing process can enable transformers to have higher working efficiency and lower iron losses.

  • Quality Control: Ensure quality control during the manufacturing process to avoid defects and inconsistencies in the core material.

6. Regular Maintenance and Inspection

  • Maintenance Measures: Regular maintenance and inspection can promptly identify and repair faults and problems in transformers. Appropriate maintenance measures can extend the service life of transformers and reduce iron losses.

  • Cleaning and Inspection: Regularly clean the surface of the transformer, inspect the insulation condition, ensure the normal operation of the transformer, and reduce losses.

Optimize the cooling system.

  • Cooling Efficiency: Optimizing the transformer's cooling system can improve the transformer's thermal balance, reducing losses and iron losses.

  • Heat dissipation design: By increasing the heat dissipation surface area and improving cooling efficiency, it can effectively reduce transformer losses.

In summary, reducing the core loss in transformers requires a multi-faceted approach, including selecting high-quality core materials, optimizing core structure, lowering magnetic flux density, choosing low-loss insulating materials, optimizing manufacturing processes, regular maintenance and inspection, and optimizing cooling systems. By combining these methods, it is possible to effectively reduce the core loss of transformers, thereby improving their efficiency and service life.

Give a tip and encourage the author!
Recommended
How to Identify Internal Faults in a Transformer?
How to Identify Internal Faults in a Transformer?
Measure DC resistance: Use a bridge to measure the DC resistance of each high- and low-voltage winding. Check whether the resistance values among phases are balanced and consistent with the manufacturer’s original data. If phase resistance cannot be measured directly, line resistance may be measured instead. The DC resistance values can indicate whether the windings are intact, whether there are short circuits or open circuits, and whether the contact resistance of the tap changer is normal. If
Felix Spark
11/04/2025
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
The tap changer operating handle shall be equipped with a protective cover. The flange at the handle shall be well sealed with no oil leakage. Locking screws shall securely fasten both the handle and the drive mechanism, and the handle rotation shall be smooth without binding. The position indicator on the handle shall be clear, accurate, and consistent with the tap voltage regulation range of the winding. Limit stops shall be provided at both extreme positions. The insulating cylinder of the t
Leon
11/04/2025
How to Overhaul a Transformer Conservator (Oil Pillow)?
How to Overhaul a Transformer Conservator (Oil Pillow)?
Overhaul Items for Transformer Conservator:1. Ordinary-Type Conservator Remove the end covers on both sides of the conservator, clean rust and oil deposits from inner and outer surfaces, then apply insulating varnish to the inner wall and paint to the outer wall; Clean components such as the dirt collector, oil level gauge, and oil plug; Check that the connecting pipe between the explosion-proof device and the conservator is unobstructed; Replace all sealing gaskets to ensure good sealing with n
Felix Spark
11/04/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli
Echo
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.