Rotary Variable Differential Transformer (RVDT)

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Rotary Variable Differential Transformer (RVDT)

The Rotary Variable Differential Transformer (RVDT) is an electromechanical transducer that transforms mechanical motion into an electrical signal. It comprises a rotor and a stator. The rotor is linked to the conductor, while the stator houses the primary and secondary windings.

The circuit of the Rotary Variable Differential Transformer (RVDT) is shown in the figure below. The working principle of the RVDT is similar to that of the Linear Variable Differential Transformer (LVDT). The only difference lies in that the LVDT uses a soft iron core to measure the displacement, while the RVDT utilizes a cam-shaped core that rotates between the primary and secondary windings with the aid of a shaft.

Theory of RVDT

ES1 and ES2 are the secondary voltages, and they change with the angular displacement of the shaft.

image.png

The G is the sensitivity of the RVDT. The secondary voltage is determined by the help of equation shown below.

image.png

The difference between ES1 – ES2 gives a proportional voltage.

image.png

The sum of the voltage is given by constant C.

image.png

Operation of Linear Variable Differential Transformer (LVDT)

When the core is in the null position, the output voltages of the secondary windings S1 and S2 are equal in magnitude but opposite in direction. The net output at the null position is zero. Any angular displacement from the null position will result in a differential output voltage. The angular displacement is directly proportional to the differential output voltage. The response of the Rotary Variable Differential Transformer (RVDT) is linear.

插图..jpg

When the shaft rotates in a clockwise direction, the differential output voltage of the transformer increases. Conversely, when the shaft rotates in an anti - clockwise direction, the differential output voltage decreases. The magnitude of the output voltage depends on both the angular displacement of the shaft and its direction of rotation.

Give a tip and encourage the author!
Recommended
How to Identify Internal Faults in a Transformer?
How to Identify Internal Faults in a Transformer?
Measure DC resistance: Use a bridge to measure the DC resistance of each high- and low-voltage winding. Check whether the resistance values among phases are balanced and consistent with the manufacturer’s original data. If phase resistance cannot be measured directly, line resistance may be measured instead. The DC resistance values can indicate whether the windings are intact, whether there are short circuits or open circuits, and whether the contact resistance of the tap changer is normal. If
Felix Spark
11/04/2025
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
The tap changer operating handle shall be equipped with a protective cover. The flange at the handle shall be well sealed with no oil leakage. Locking screws shall securely fasten both the handle and the drive mechanism, and the handle rotation shall be smooth without binding. The position indicator on the handle shall be clear, accurate, and consistent with the tap voltage regulation range of the winding. Limit stops shall be provided at both extreme positions. The insulating cylinder of the t
Leon
11/04/2025
How to Overhaul a Transformer Conservator (Oil Pillow)?
How to Overhaul a Transformer Conservator (Oil Pillow)?
Overhaul Items for Transformer Conservator:1. Ordinary-Type Conservator Remove the end covers on both sides of the conservator, clean rust and oil deposits from inner and outer surfaces, then apply insulating varnish to the inner wall and paint to the outer wall; Clean components such as the dirt collector, oil level gauge, and oil plug; Check that the connecting pipe between the explosion-proof device and the conservator is unobstructed; Replace all sealing gaskets to ensure good sealing with n
Felix Spark
11/04/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli