Transformers Insulation Materials in Oil-Immersed & Dry Type T/F

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Insulation in Oil-Immersed Transformers

In contemporary oil - immersed transformers, the insulation of high - voltage windings follows a widely adopted approach. Typically, the wire is coated with enamel, and kraft paper is inserted between each layer of the winding. This combination provides reliable electrical insulation and mechanical protection for the high - voltage windings, safeguarding them against electrical breakdown and physical damage.

For low - voltage windings, a different insulation strategy is employed. Here, the strip conductors can be left bare, with paper insulation placed between the layers. This method strikes a balance between cost - effectiveness and the necessary insulation requirements for low - voltage applications.

However, the landscape of insulation materials for strap conductors in low - voltage windings is evolving. The traditional practice of wrapping strap conductors with paper is gradually being phased out. Synthetic polymer coatings and wraps made from synthetic cloth are emerging as preferred alternatives. These modern materials offer enhanced durability, better electrical insulation properties, and improved resistance to environmental factors compared to traditional paper insulation.

The incorporation of aluminum wire, strap, and strip conductors, along with enamel coatings, has presented unique challenges to distribution transformer manufacturers. Aluminum has a distinctive property: when exposed to air, it spontaneously forms an insulating oxide layer on its surface. This self - formed oxide coating can impede electrical conductivity. As a result, whenever electrical connections need to be established using aluminum conductors, manufacturers must devise effective methods to either remove this oxide layer or prevent its formation at the connection points. This requires careful material selection, precise manufacturing processes, and strict quality control measures to ensure the reliable operation of distribution transformers with aluminum - based components.

image.png

Challenges and Solutions with Aluminum Conductors in Transformers, and Insulation in Dry-Type Transformers

Challenges and Handling of Aluminum Conductors in Oil-Immersed Transformers

Furthermore, electrical - conductor - grade aluminum possesses a notably soft texture. When mechanical clamping is applied, it is highly susceptible to issues such as cold flow and differential expansion. Cold flow refers to the slow deformation of the soft aluminum under mechanical stress over time, while differential expansion occurs when aluminum expands or contracts at a different rate than other components in the assembly, potentially leading to loose connections or mechanical failures.

To address the connectivity needs of aluminum wires, several specialized splicing methods have been developed. Soldering can be used, although it requires specific soldering techniques and fluxes to ensure a good bond. Another common approach is crimping, which involves using special crimps. These crimps are designed to penetrate both the enamel coating on the wire and the naturally formed oxide layer on the aluminum surface. By doing so, they establish a reliable electrical connection. Additionally, they seal off the contact areas from oxygen, preventing further oxidation and ensuring the long - term integrity of the connection.

For aluminum strap or strip conductors, TIG (tungsten inert gas) welding offers an effective joining solution. This welding process uses a non - consumable tungsten electrode and an inert gas shield to create a high - quality, strong bond between the aluminum components. Moreover, aluminum strips can also be joined to other copper or aluminum connectors through cold welding or crimping techniques. Cold welding, in particular, creates a solid - state bond without the need for melting the materials, which is beneficial for maintaining the mechanical and electrical properties of the conductors. Even for making bolted connections to soft aluminum, as long as the joint area is meticulously cleaned to remove any oxide or contaminants, a secure and electrically conductive connection can be achieved.

Insulation Materials in Dry - Type Transformers

In the realm of dry - type transformers, a standard practice is to apply a protective seal or coating to the windings using resin or varnish. This serves as a safeguard against various adverse environmental factors, such as moisture, dust, and corrosive gases, all of which can gradually degrade the insulation properties of the transformer windings and compromise the overall performance and lifespan of the transformer.

The insulating media utilized for the primary and secondary windings of dry - type transformers can be classified into the following distinct categories:

  • Cast Coil: In this type, the winding is embedded in a cast resin, which provides a robust and durable insulation structure. The cast resin not only encapsulates the conductors but also offers excellent mechanical strength and electrical insulation, making it suitable for applications where high reliability and protection are required.

  • Vacuum - Pressure Encapsulated: This method involves encapsulating the windings under vacuum - pressure conditions. By removing air and other contaminants from the insulation process, it ensures a more uniform and void - free insulation layer, enhancing the electrical and thermal performance of the transformer.

  • Vacuum - Pressure Impregnated: Here, the windings are immersed in an insulating resin under vacuum - pressure. This process allows the resin to penetrate deeply into the winding structure, filling all the gaps and pores. As a result, it provides enhanced insulation and heat - dissipation capabilities, contributing to the efficient operation of the transformer.

  • Coated: Simple coating techniques involve applying a layer of insulating material, such as varnish or a specialized coating compound, directly onto the windings. This type of insulation is relatively straightforward and cost - effective, suitable for applications where less stringent insulation requirements are needed.

Insulation Materials.jpg

Cast Coil

In the cast coil insulation method, the winding is first reinforced as needed or positioned within a mold. Then, it is cast in resin under vacuum - pressure conditions. This process offers several significant advantages. Since the winding is fully encased in solid insulation, it effectively reduces sound levels during operation. Additionally, the vacuum - pressure casting process fills the winding with resin, completely eliminating any voids. These voids, if present, could lead to corona discharge, which can degrade the insulation and cause electrical problems over time. With its solid insulation system, the cast coil winding boasts exceptional mechanical strength, enabling it to withstand mechanical stresses. It also has remarkable short - circuit strength, ensuring reliable performance during electrical faults. Moreover, this type of winding is highly resistant to moisture and contaminants, safeguarding the transformer's internal components and extending its lifespan.

Vacuum - Pressure Encapsulated

For the vacuum - pressure encapsulated insulation, the winding is embedded in resin under vacuum - pressure. Similar to the cast coil process, encapsulating the winding with resin in this way effectively removes any voids that might otherwise give rise to corona. As a result, the winding benefits from excellent mechanical strength, allowing it to endure mechanical shocks and vibrations. It also exhibits high short - circuit strength, ensuring stable operation during abnormal electrical conditions. This insulation method provides robust protection against moisture ingress and the intrusion of contaminants, maintaining the integrity of the winding and the overall performance of the transformer.

Vacuum - Pressure Impregnated

In the vacuum - pressure impregnated insulation technique, the winding is permeated with varnish under vacuum - pressure. The impregnation process coats the winding thoroughly, creating a protective layer that shields it from moisture and contaminants. This helps to preserve the electrical and mechanical properties of the winding, ensuring reliable operation of the transformer in various environmental conditions. Although the level of protection might be relatively less comprehensive compared to some other methods, it still offers sufficient safeguarding for many applications.

Coated

The coated insulation approach involves dipping the winding in varnish or resin. A coated winding provides a basic level of protection against moisture and contaminants, making it suitable for use in moderate environments where the risk of exposure to harsh elements is relatively low. While it may not offer the same level of protection as more elaborate insulation methods, it is a cost - effective and straightforward solution for applications with less demanding insulation requirements.

Give a tip and encourage the author!
Recommended
How to Identify Internal Faults in a Transformer?
How to Identify Internal Faults in a Transformer?
Measure DC resistance: Use a bridge to measure the DC resistance of each high- and low-voltage winding. Check whether the resistance values among phases are balanced and consistent with the manufacturer’s original data. If phase resistance cannot be measured directly, line resistance may be measured instead. The DC resistance values can indicate whether the windings are intact, whether there are short circuits or open circuits, and whether the contact resistance of the tap changer is normal. If
Felix Spark
11/04/2025
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
The tap changer operating handle shall be equipped with a protective cover. The flange at the handle shall be well sealed with no oil leakage. Locking screws shall securely fasten both the handle and the drive mechanism, and the handle rotation shall be smooth without binding. The position indicator on the handle shall be clear, accurate, and consistent with the tap voltage regulation range of the winding. Limit stops shall be provided at both extreme positions. The insulating cylinder of the t
Leon
11/04/2025
How to Overhaul a Transformer Conservator (Oil Pillow)?
How to Overhaul a Transformer Conservator (Oil Pillow)?
Overhaul Items for Transformer Conservator:1. Ordinary-Type Conservator Remove the end covers on both sides of the conservator, clean rust and oil deposits from inner and outer surfaces, then apply insulating varnish to the inner wall and paint to the outer wall; Clean components such as the dirt collector, oil level gauge, and oil plug; Check that the connecting pipe between the explosion-proof device and the conservator is unobstructed; Replace all sealing gaskets to ensure good sealing with n
Felix Spark
11/04/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli