• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Outdoor Substations: Types, Pros & Cons (55kV–765kV)

Edwiin
Edwiin
Field: Power switch
China

Substations designed for voltage levels ranging from 55 kV to 765 kV are known as outdoor substations. This type of substation requires less construction time but occupies more space. Outdoor substations are mainly divided into pole-mounted substations and foundation-mounted substations.

Pole-Mounted Substations

This type of substation is used to support distribution transformers with capacities up to 250 kVA. Such transformers represent the cheapest, simplest, and smallest form of distribution. All equipment is of outdoor type and installed on the supporting structures of high-voltage distribution lines. A three-pole mechanically operated switch is used to open and close the high-voltage transmission line.

High-tension (HT) fuses are used to protect the high-voltage transmission line. For controlling the low-voltage circuit, low-voltage switches and fuses are provided. Surge arresters are installed on the high-voltage lines to protect the transformer from voltage surges. Pole-mounted substations are grounded at two or more locations.

Transformers with capacities up to 125 kVA are mounted on a two-pole structure, while transformers rated between 125 kVA and 250 kVA are installed on a four-pole structure with an appropriate platform. This type of substation is typically placed in densely populated areas.

They have low maintenance costs, and by deploying a large number of such substations in towns, it is expected that distribution networks can be established at lower cost. However, as the number of transformers increases, the total kVA increases, but load losses do not rise proportionally, leading to an increase in cost per kVA.

Foundation-Mounted Substations

In foundation-mounted substations, all equipment areas are assembled for safety purposes, and the entire substation is enclosed within a fence. The equipment used in such substations is heavy; therefore, the selected site must have good access for heavy transportation.

Advantages of Outdoor Substations

Outdoor substations offer the following main advantages:

  • All equipment in an outdoor substation is visible, making fault location easier.

  • Expansion of outdoor substations is simpler.

  • Construction time required for this type of substation is shorter.

  • Less construction material—such as steel and concrete—is needed.

  • Relatively less construction work is required, and the cost of installing switchgear is low.

  • Maintenance is easy, and adequate spacing between equipment ensures that a fault at one point does not propagate to another.

Disadvantages of Outdoor Substations

  • Outdoor substations require more space.

  • Protective devices must be installed to guard against lightning surge effects.

  • The length of control cables increases, raising the overall cost of the substation.

  • Equipment designed for outdoor substations is more expensive because it requires additional dust and weather protection.

Despite these disadvantages, outdoor substations are widely used in power systems.

Give a tip and encourage the author!
Recommended
Selection Principles and Precautions for Fuse-Switch Disconnectors
Selection Principles and Precautions for Fuse-Switch Disconnectors
The selection principles and precautions for fuse-switch disconnectors are crucial to ensuring the safe and stable operation of power systems.Selection Principles for Fuse-Switch Disconnectors Rated Voltage:The rated voltage of the fuse-switch disconnector shall be equal to or greater than the rated voltage of the electrical system to ensure the equipment operates normally without damage. Rated Current:The selection of rated current should be based on the load conditions of the electrical system
James
11/06/2025
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
Six Troubleshooting Tips for Stepper Servo Motor Issues
Six Troubleshooting Tips for Stepper Servo Motor Issues
Stepper servo motors, as critical components in industrial automation, directly impact equipment performance through their stability and precision. However, in practical applications, motors may exhibit abnormalities due to parameter configuration, mechanical load, or environmental factors. This article provides systematic solutions for six typical issues, combined with real-world engineering cases, to help technicians quickly identify and resolve problems.1. Abnormal Motor Vibration and NoiseVi
Felix Spark
11/06/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.