Basic Signal Operations

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Are The Basic Signal Operations

A signal, comprises of a set of information expressed as a function of any number of independent variables, that can be given as an input to a system, or derived as output from the system, to realize its true practical utility. The signal we derive out of a complex system might not always be in the form we want,
∴ being well acquainted with some basic signal operations may come really handy to enhance the understandability and applicability of signals.
The mathematical transformation from one signal to another can be expressed as

Where, Y(t) represents the modified signal derived from the original signal X(t), having only one independent variable t.
The basic set of signal operations can be broadly classified as below.

Basic Signal Operations Performed on Dependent Variables

In this transformation, only the quadrature axis values are modified i.e magnitude of the signal changes, with no effects on the horizontal axis values or periodicity of signals like.

  1. Amplitude scaling of signals.

  2. Addition of signals.

  3. Multiplication of signals.

  4. Differentiation of signals.

  5. Integration of signals.

Let us look into these types in details.

Amplitude Scaling of Signals

Amplitude scaling is a very basic operation performed on signals to vary its strength. It can be mathematically represented as Y(t) = α X(t).
Here, α is the scaling factor, where:-
          α<1 → signal is attenuated.
          α>1 → signal is amplified.
basic signal operation
This is illustrated in the diagram, where the signal is attenuated when α = 0.5 in fig (b) and amplified when α = 1.5 as in fig (c).

Addition of Signals

This particular operation involves the addition of amplitude of two or more signals at each instance of time or any other independent variables which are common between the signals. Addition of signals is illustrated in the diagram below, where X1(t) and X2(t) are two time dependent signals, performing the additional operation on them we get,

addition of signal

Multiplication of Signals

Like addition multiplication of signals also falls under the category of basic signal operations. Here multiplication of amplitude of two or more signals at each instance of time or any other independent variables is done which are common between the signals. The resultant signal we get has values equal to the product of amplitude of the parent signals for each instance of time. Multiplication of signals is illustrated in the diagram below, where X1(t) and X2(t) are two time dependent signals, on whom after performing the multiplication operation we get,

multiplication of signal

Differentiation of Signals

differentiation of signal
For differentiation of signals, it must be noted that this operation is only applicable for only continuous signals, as a discrete function cannot be differentiated. The modified signal we get on differentiation has tangential values of the parent signal at all instance of time. Mathematically it can be expressed as:-

Differentiation of a standard square and sine wave is shown in the figure below.

Integration of Signals

Like differentiation, integration of signals is also applicable to only continuous time signals. The limits of integration will be from – ∞ to present instance of time t. It is mathematically expressed as,

Integration of some continuous time signals is shown in the diagram below.
differentiation of signal

Basic Signal Operations Performed on Dependent Variables

This is exactly the opposite of the above mentioned case, here the periodicity of the signal is varied by modifying the horizontal axis values, while the amplitude or the strength remains constant. These are:-

  1. Time scaling of signals

  2. Reflection of signals

  3. Time-shifting of signals.

Let us look into these operations in details.

Time Scaling of Signals

Time scaling of signals of signals involves the modification of a periodicity of the signal, keeping its amplitude constant. Its mathematically expressed as,

Where, X(t) is the original signal, and β is the scaling factor.
If β > 1 implies, the signal is compressed and β < 1 implies, the signal is expanded. This is illustrated diagrammatically for better understanding.
time scaling of signal

Reflection of Signals

Reflection of signal is a very interesting operation applicable on both continuous and discrete signals. Here in this case the vertical axis acts as the mirror, and the transformed image obtained is exactly the mirror image of the parent signal.
It can be defined as Y(t) = X(- t) Where, X(t) is the original signal.
But if the reflected signal X(- t) = X(t); then its called an even signal.
Where as when X(- t) = − X(t); then its known as an odd signal.
Its explained diagrammatically as,
reflection of signal

Time Shifting of Signals

Time shifting of signals is probably the most important one, and most widely used amongst all basic signal operations. Its generally used to fast-forward or delay a signal, as is necessary in most practical circumstances. Time shifting is mathematically expressed as,

Where, X(t) is the original signal, and t0 represents the shift in time.
For a signal X(t) if the position shift t0> 0. Then the signal is said to be right shifted or delayed.
In the same manner, if t0 < 0, implies the signal is left shifted or delayed. This has been explained diagrammatically in the figure below. Where the original signal fig(a) is right shifted and also left shifted in figure (b) and (c) respectively.
time shifting of signal

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.