Nyquist Plot: What is it? (And How To Draw One)

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is A Nyquist Plot

What is a Nyquist Plot?

A Nyquist plot (or Nyquist Diagram) is a frequency response plot used in control engineering and signal processing. Nyquist plots are commonly used to assess the stability of a control system with feedback. In Cartesian coordinates, the real part of the transfer function is plotted on the X-axis, and the imaginary part is plotted on the Y-axis.

The frequency is swept as a parameter, resulting in a plot based on frequency. The same Nyquist plot can be described using polar coordinates, where the gain of the transfer function is the radial coordinate, and the phase of the transfer function is the corresponding angular coordinate.



What is Nyquist Plot



The stability analysis of a feedback control system is based on identifying the location of the roots of the characteristic equation on the s-plane.

The system is stable if the roots lie on the left-hand side of the s-plane. The relative stability of a system can be determined by using frequency response methods – such as the Nyquist plot, Nichols plot, and Bode plot.

The Nyquist stability criterion is used to identify the presence of roots of a characteristic equation in a specified region of the s-plane.

To understand a Nyquist plot we first need to learn about some of the terminologies. Note that a closed path in a complex plane is called a contour.

Nyquist Path or Nyquist Contour

The Nyquist contour is a closed contour in the s-plane which completely encloses the entire right-hand half of the s-plane.

In order to enclose the complete RHS of the s-plane, a large semicircle path is drawn with a diameter along jω axis and center at the origin. The radius of the semicircle is treated as Nyquist Encirclement.

Nyquist Encirclement

A point is said to be encircled by a contour if it is found inside the contour.

Nyquist Mapping

The process by which a point in the s-plane is transformed into a point in the F(s) plane is called mapping and F(s) is called the mapping function.

How to Draw Nyquist Plot

A Nyquist plot can be drawn using the following steps:

  • Step 1 – Check for the poles of G(s) H(s) of the jω axis including that at the origin.

  • Step 2 – Select the proper Nyquist contour – a) Include the entire right half of the s-plane by drawing a semicircle of radius R with R tends to infinity.

  • Step 3 – Identify the various segments on the contour with reference to the Nyquist path

  • Step 4 – Perform the mapping segment by segment by substituting the equation for the respective segment in the mapping function. Basically, we have to sketch the polar plots of the respective segment.

  • Step 5 – Mapping of the segments are usually mirror images of mapping of the respective path of +ve imaginary axis.

  • Step 6 – The semicircular path which covers the right half of s plane generally maps into a point in G(s) H(s) plane.

  • Step 7- Interconnect all the mapping of different segments to yield the required Nyquist diagram.

  • Step 8 – Note the number of clockwise encirclements about (-1, 0) and decide stability by N = Z – P


is the Open loop transfer function (O.L.T.F)


is the Closed loop transfer function (C.L.T.F)
N(s) = 0 is the open loop zero and D(s) is the open loop pole
From a stability point of view, no closed loop poles should lie on the RH side of the s-plane. Characteristics equation 1 + G(s) H(s) = 0 denotes closed-loop poles .

Now as 1 + G(s) H(s) = 0 hence q(s) should also be zero.

Therefore, from the stability point of view zeroes of q(s) should not lie in the RHP of the s-plane.
To define the stability entire RHP (Right-Hand Plane) is considered. We assume a semicircle that encloses all points in the RHP by considering the radius of the semicircle R tends to infinity. [R → ∞].

The first step to understanding the application of the Nyquist criterion in relation to the determination of stability of control systems is mapping from the s-plane to the G(s) H(s) – plane.

s is considered an independent complex variable and the corresponding value of G(s) H(s) is the dependent variable plotted in another complex plane called the G(s) H(s) – plane.

Thus for every point in the s-plane, there exists a corresponding point in G(s) H(s) – plane. During the process of mapping, the independent variable s is varied along a specified path in the s-plane, and the corresponding points in G(s)H(s) plane are joined. This completes the process of mapping from the s-plane to the G(s)H(s) – plane.

Nyquist stability criterion says that N = Z – P. Where, N is the total no. of encirclement about the origin, P is the total no. of poles and Z is the total no. of zeroes.
Case 1: N = 0 (no encirclement), so Z = P = 0 and Z = P
If N = 0, P must be zero therefore the system is stable.
Case 2: N > 0 (clockwise encirclement), so P = 0, Z ≠0 and Z > P
In both cases the system is unstable.
Case 3: N < 0 (counter-clockwise encirclement), so Z = 0, P ≠0 and P > Z
The system is stable.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.