What is a Nichols Chart?

A Nichols Chart (also known as a Nichols Plot) is a plot used in signal processing and control system design to determine the stability and closed-loop frequency response of a feedback system. The Nichols chart is named after its founder, Nathaniel B. Nichols.

How Does A Nichols Chart Work?

Constant magnitude loci that are M-circles and constant phase angle loci that are N-circles are the fundamental components in designing the Nichols chart.

The constant M and constant N circles in the G (jω) plane can be used to analyze and design control systems.

However, the constant M and constant N circles in the gain phase plane are prepared for system design and analysis as these plots supply information with fewer manipulations.

The gain phase plane is the graph having gain in decibels along the ordinate (vertical axis) and phase angle along the abscissa (horizontal axis).

The M and N circles of G (jω) in the gain phase plane are transformed into M and N contours in rectangular coordinates.

A point on the constant M loci in G (jω) plane is transferred to the gain phase plane by drawing the vector directed from the origin of the G (jω) plane to a particular point on the M circle and then measuring the length in dB and angle in degree.

The critical point in G (jω), plane corresponds to the point of zero decibels and -180o in the gain phase plane. The plot of M and N circles in the gain phase plane is known as the Nichols chart (or Nichols plot).

Compensators can be designed using a Nichols plot.

The Nichols plot technique is also used in the design of a DC motor. This is used in signal processing and control system design.

The related Nyquist plot in the complex plane shows how the phase of the transfer function and frequency variation of magnitude are related. We can find out the gain and phase for a given frequency.

The angle of the positive real axis determines the phase and the distance from the origin of the complex plane determines the gain. There are some advantages of Nichols’ plot in control system engineering.

They are:

  • Gain and phase margins can be determined easily and also graphically.

  • Closed loop frequency response is obtained from open loop frequency response.

  • The gain of the system can be adjusted to suitable values.

  • Nichols chart provides frequency domain specifications.

There are also some drawbacks to the Nichols plot. Using a Nichols plot is difficult for small changes in gain.

Constant M and N circles in the Nichols chart are deformed into squashed circles.

The complete Nichols chart extends for the phase angle of G (jω) from 0 to -360o. The region of ∠G(jω) is used for the analysis of systems between -90o to -270o. These curves repeat after every 180o interval.

If the open loop T.F of unity feedback system G(s) is expressed as

Closed loop T.F is

Substituting s = jω in the above eq. frequency functions are,

and

Eliminating G(jω) from the above two eq.

and

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.