Buchholz Relay Function | Oil Level & Gas Fault Detection for Transformer Protection

Rockwell
Rockwell
Field: Manufacturing
China

Revised and Polished Version:

The Buchholz relay is a critical protective device used in oil-immersed transformers, serving multiple key functions to ensure safe and reliable operation:

1. Monitoring Oil Level Changes:

The relay continuously monitors the oil level within the transformer tank. A drop in oil level—often caused by leaks or oil loss—can compromise the transformer’s insulation and cooling capabilities, potentially leading to overheating or insulation failure. The Buchholz relay detects such changes and initiates appropriate alarm or shutdown actions.

2. Detecting Gas Accumulation:

Under abnormal operating conditions, such as insulation aging, localized overheating, or partial discharges, insulating materials and transformer oil may decompose and generate gases like hydrogen, methane, ethylene, and acetylene. The Buchholz relay detects the accumulation of these fault-generated gases in the oil, providing an early indication of developing internal problems.

3. Identifying Internal Faults:

In the event of serious internal faults—such as winding insulation breakdown, arcing, or severe short circuits—rapid gas generation occurs, often accompanied by a surge of oil flow. The Buchholz relay is designed to sense both the slow accumulation of gases (for minor faults) and sudden oil displacement (for major faults), triggering alarm signals for minor issues and initiating immediate tripping of the transformer for severe faults.

4. Providing Protective Actions:

Upon detecting abnormal conditions, the Buchholz relay activates protective measures. It typically has two sets of contacts: one for alarm (activated by gas accumulation) and another for tripping (activated by sudden oil flow due to major faults). This dual-stage response helps prevent catastrophic damage and enhances system safety.

Conclusion:

In summary, the Buchholz relay plays a vital role in the early detection of incipient faults within oil-immersed transformers. By monitoring oil levels and gas formation, it enables timely intervention, minimizes damage, and significantly improves the reliability and longevity of the transformer. As such, it is an indispensable safety component in power transformer protection systems.

Give a tip and encourage the author!
Recommended
What causes a transformer to be noisier under no-load conditions?
What causes a transformer to be noisier under no-load conditions?
When a transformer is operating under no-load conditions, it often produces louder noise than under full load. The primary reason is that, with no load on the secondary winding, the primary voltage tends to be slightly higher than nominal. For example, while the rated voltage is typically 10 kV, the actual no-load voltage may reach around 10.5 kV.This elevated voltage increases the magnetic flux density (B) in the core. According to the formula:B = 45 × Et / S(where Et is the designed volts-per-
Noah
11/05/2025
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
When installing an arc suppression coil, it is important to identify the conditions under which the coil should be taken out of service. The arc suppression coil should be disconnected under the following circumstances: When a transformer is being de-energized, the neutral-point disconnector must be opened first before performing any switching operations on the transformer. The energizing sequence is the reverse: the neutral-point disconnector should be closed only after the transformer is energ
Echo
11/05/2025
What fire prevention measures are available for power transformer failures?
What fire prevention measures are available for power transformer failures?
Failures in power transformers are commonly caused by severe overload operation, short circuits due to winding insulation degradation, aging of transformer oil, excessive contact resistance at connections or tap changers, failure of high- or low-voltage fuses to operate during external short circuits, core damage, internal arcing in oil, and lightning strikes.Since transformers are filled with insulating oil, fires can have severe consequences—ranging from oil spraying and ignition to, in extrem
Noah
11/05/2025
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
Transformer Longitudinal Differential Protection: Common Issues and SolutionsTransformer longitudinal differential protection is the most complex among all component differential protections. Misoperations occasionally occur during operation. According to 1997 statistics from the North China Power Grid for transformers rated 220 kV and above, there were 18 incorrect operations in total, of which 5 were due to longitudinal differential protection—accounting for approximately one-third. Causes of
Felix Spark
11/05/2025