What are the characteristics of insulating materials used in transformers?

Encyclopedia
Field: Encyclopedia
0
China

The insulating materials used in transformers have the following characteristics:

High resistivity and low conductivity: Insulating materials are substances with high resistivity and low conductivity, capable of effectively isolating conductors with electric charge or different potentials, ensuring that current flows in a specific direction.

  • Multifunctionality: In addition to their basic insulating function, transformer insulation materials also serve various purposes such as heat dissipation, cooling, support, arc extinction, improvement of potential gradients, moisture and mold resistance, and protection of conductors.

  • Heat Resistance Grade: The heat resistance grade of insulating materials refers to the highest temperature they can withstand in a transformer. Proper use of insulating materials can ensure a 30-year lifespan, but excessive temperatures can cause insulation aging and affect the service life.

  • Variety of Materials: Transformer insulation materials include solid insulating materials (such as insulating paper, cardboard, Nomex paper, epoxy glass cloth board, etc.), liquid insulating materials (such as transformer oil), and gaseous insulating materials (such as SF6 gas, nitrogen, etc.).

  • Performance and Application: With the advancement of technology, new insulating materials are constantly emerging. These new materials may have significant performance improvements, such as better aging resistance and higher insulation strength, thereby enhancing the reliability and service life of transformers.

  • Adapt to Different Environments: Transformers operating in high-altitude areas require special consideration for the performance of insulation materials to adapt to lower atmospheric pressure and possible low-temperature environments.

To sum up, the insulating materials of transformers are their core components, and their selection and performance directly affect the operation efficiency and safety of the equipment.



Give a tip and encourage the author!

Recommended

Analysis of Lightning Protection Measures for Distribution Transformers
Analysis of Lightning Protection Measures for Distribution TransformersTo prevent lightning surge intrusion and ensure the safe operation of distribution transformers, this paper presents applicable lightning protection measures that can effectively enhance their lightning withstand capability.1. Lightning Protection Measures for Distribution Transformers1.1 Install surge arresters on the high-voltage (HV) side of the distribution transformer.According to SDJ7–79 Technical Code for Overvol
12/24/2025
Transformer Protection Settings: Zero-Sequence & Overvoltage Guide
1. Zero-Sequence Overcurrent ProtectionThe operating current for zero-sequence overcurrent protection of grounding transformers is typically determined based on the transformer's rated current and the maximum allowable zero-sequence current during system ground faults. The general setting range is approximately 0.1 to 0.3 times the rated current, with operating time usually set between 0.5 to 1 second to quickly clear ground faults.2.Overvoltage ProtectionOvervoltage protection is a critical com
12/17/2025
Electrical Protection: Grounding Transformers and Bus Charging
1. High-Resistance Grounding SystemHigh-resistance grounding can limit ground fault current and appropriately reduce ground overvoltage. However, there is no need to connect a large high-value resistor directly between the generator neutral point and ground. Instead, a small resistor can be used together with a grounding transformer. The primary winding of the grounding transformer is connected between the neutral point and ground, while the secondary winding is connected to a small resistor. Ac
12/17/2025
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an