Can Copper PVC Cable Be Used to Connect to Air Terminals in Lightning Protection Systems?

Encyclopedia
Field: Encyclopedia
0
China

In lightning protection systems, the selection of conductive materials and types for connecting air terminals (lightning rods) is very important. Using copper PVC cable to connect to air terminals is not the best choice, and the main reasons are as follows:

1. Conductivity

  • Copper Wire: Copper is an excellent conductor and can effectively carry lightning current.

  • PVC Insulation Layer: The PVC insulation layer may melt or burn due to high temperatures during a lightning strike, affecting conductivity and safety.

2. Weather Resistance and Corrosion Resistance

  • Copper Wire: Copper has good weather resistance and corrosion resistance, making it suitable for long-term outdoor exposure.

  • PVC Insulation Layer: The PVC insulation layer can degrade over time when exposed to UV radiation, humidity, and temperature changes, reducing its insulating properties and mechanical strength.

3. Standards and Regulations

  • International and National Standards: Many international and national standards (such as IEC 62561, NFPA 780, GB 50057, etc.) have clear specifications for the materials and types of conductors used in lightning protection systems. These standards typically recommend the use of bare copper wire or tinned copper wire, rather than insulated cables.

  • Safety and Reliability: The materials and types specified by standards are designed to ensure the safety and reliability of lightning protection systems. Using non-compliant materials can pose safety hazards.

4. Installation and Maintenance

  • Bare Copper Wire: Bare copper wire is easy to install and inspect, allowing for a clear visual check of the wire's condition.

  • Copper PVC Cable: During installation and maintenance, the insulation layer of copper PVC cable can be damaged, affecting conductivity and safety.

Recommended Practices

  • Bare Copper Wire: It is recommended to use bare copper wire to connect air terminals. The wire cross-sectional area should be selected based on the magnitude of the lightning current and standard requirements.

  • Tinned Copper Wire: Tinned copper wire can also be used to improve corrosion resistance.

  • Grounding System: Ensure that the connection between the wire and the grounding system is reliable, and the grounding resistance should meet standard requirements.

Conclusion

Although copper PVC cable has good conductivity, its insulation layer can be damaged during a lightning strike, and it has weather resistance issues when exposed to outdoor conditions for a long time. Therefore, it is not recommended to use copper PVC cable to connect to air terminals in lightning protection systems. It is recommended to use bare copper wire or tinned copper wire to ensure the safety and reliability of the lightning protection system. 

Give a tip and encourage the author!

Recommended

Analysis of Lightning Protection Measures for Distribution Transformers
Analysis of Lightning Protection Measures for Distribution TransformersTo prevent lightning surge intrusion and ensure the safe operation of distribution transformers, this paper presents applicable lightning protection measures that can effectively enhance their lightning withstand capability.1. Lightning Protection Measures for Distribution Transformers1.1 Install surge arresters on the high-voltage (HV) side of the distribution transformer.According to SDJ7–79 Technical Code for Overvol
12/24/2025
Transformer Protection Settings: Zero-Sequence & Overvoltage Guide
1. Zero-Sequence Overcurrent ProtectionThe operating current for zero-sequence overcurrent protection of grounding transformers is typically determined based on the transformer's rated current and the maximum allowable zero-sequence current during system ground faults. The general setting range is approximately 0.1 to 0.3 times the rated current, with operating time usually set between 0.5 to 1 second to quickly clear ground faults.2.Overvoltage ProtectionOvervoltage protection is a critical com
12/17/2025
Electrical Protection: Grounding Transformers and Bus Charging
1. High-Resistance Grounding SystemHigh-resistance grounding can limit ground fault current and appropriately reduce ground overvoltage. However, there is no need to connect a large high-value resistor directly between the generator neutral point and ground. Instead, a small resistor can be used together with a grounding transformer. The primary winding of the grounding transformer is connected between the neutral point and ground, while the secondary winding is connected to a small resistor. Ac
12/17/2025
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.