• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


What is the purpose of grounding the neutral wire? How does grounding differ from bonding in terms of safety?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Purpose of neutral grounding

Provide reference potential

In a power system, neutral grounding provides a stable reference potential for the entire circuit, which is usually defined as zero potential. This helps determine the voltage value of other lines (such as the fireline) with respect to this zero potential, making voltage measurement and analysis more convenient and accurate. For example, in a three-phase four-wire low-voltage distribution system (380V/220V), the voltage between the live line and the neutral line is 220V, and this voltage value is determined based on the zero potential of the neutral line.

Ensure the stable operation of the system

For three-phase unbalanced load, neutral grounding can ensure the relative stability of three-phase voltage. When the three-phase load is unbalanced (for example, in some residential areas or small commercial power scenarios, the number and power of electrical equipment connected on different phases are different), the neutral line can direct the unbalanced current back to the neutral point of the power supply to avoid affecting the normal operation of the electrical equipment due to the three-phase voltage imbalance. If the neutral line is not grounded, the three-phase imbalance may cause the voltage of each phase to fluctuate greatly, affecting the service life of the device or even damaging the device.

Fault protection

In the event of a single-phase ground fault, neutral grounding helps the fault current flow quickly. For example, when a live wire is accidentally grounded, the grounded neutral line provides a low-impedance return path for the fault current, so that the protection device (such as fuses, circuit breakers, etc.) can detect the fault current in time and act to cut off the circuit, thus protecting personal safety and equipment safety.

Difference in safety between grounding and zero connection

Different protection principles

  • Grounding (protective grounding) : Protective grounding is the reliable connection between the metal shell or frame of the electrical equipment and the earth. When a leakage fault occurs in the equipment, such as the winding insulation of the motor is damaged so that the housing is charged, because the housing is grounded, the leakage current will flow into the earth through the grounding resistance. If the grounding resistance is small enough to make the grounding current reach the operating current threshold of the protection device (such as the leakage protector), the protection device will act to cut off the circuit; If the grounding resistance is large, although the protection device cannot be activated immediately, when the human body contacts the charged shell, because the human body resistance is much larger than the grounding resistance, most of the leakage current will flow into the earth through the grounding resistance, thereby reducing the current through the human body and reducing the risk of electric shock.

  • Zero connection (protective zero connection) : The protective zero connection is to connect the metal shell of the electrical equipment to the neutral line (neutral line). In the three-phase four-wire system, if the equipment leakage occurs, such as a fire line and the equipment housing short circuit, then the phase of the short circuit current will return to the power supply through the neutral line, the short circuit current is usually large, will quickly make the fuse on the line to fuse or circuit breaker trip, thus cutting off the power supply to prevent human shock.

Different scope of application

  • Grounding: Suitable for power systems with neutral points ungrounded or grounded by high impedance, such as simple distribution systems in some rural areas or some special industrial power systems. In these systems, because the effective fault protection cannot be realized through zero connection, grounding is an important means to ensure safety.

  • Zero connection: It is mainly suitable for three-phase four-wire low-voltage distribution system with direct grounding of neutral point (such as common 380V/220V system). In this kind of system, the neutral line has been grounded, and the leakage protection can be realized quickly and effectively by using the protective zero connection.

The voltage at the time of failure is different

  • Grounding: In a protective grounding system, when a leakage fault occurs in the device, the voltage to ground of the device housing is equal to the leakage current multiplied by the grounding resistance. If the grounding resistance is large, the device enclosure may carry a high voltage to the ground. Although the current passing through the human body is relatively small, there is still a risk of electric shock.

  • Zero connection: In the protective zero connection system, once the equipment leakage occurs, because the short-circuit current returns to the power supply through the neutral line, the theoretical voltage to the ground of the equipment housing will quickly drop to close to zero volts, greatly improving safety.

Give a tip and encourage the author!
Recommended
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.