• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


What is a Thermal Relay?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is a  Thermal Relay?


Thermal relay definition


A thermal relay is defined as a device that uses unequal expansion rates of metals in a bimetallic strip to detect overcurrent conditions.



6ca40a1b4fe123a136af1bfeb13a1f61.jpeg



Working principle


Thermal relays work by heating a bimetallic strip, causing it to bend and close the normally open contact, which triggers the circuit breaker.



Construction of thermal relay


It consists of a bimetallic strip, metal with different expansion coefficients, a heating coil and contacts.




27e4e0793a6cdb2d64df605dc9ccc534.jpeg



Technical parameter


  • Rated voltage

  • Rated current

  • Rated frequency

  • Set the current range




Delay function


The heating effect of the relay follows Joule's law, resulting in a delay in operation, allowing temporary overload without tripping.



Install


When the thermal relay is installed with other electrical appliances, it should be installed under the electrical appliances and more than 50mm away from other electrical appliances, so as not to be affected by the heating of other electrical appliances.



Routine maintenance


  • It takes a certain amount of time to reset the thermal relay after operation, the automatic reset time should be completed within 5 minutes, and the manual reset button can be pressed after 2 minutes.


  • After a short circuit fault occurs, check whether the thermal element and bimetal sheet are deformed


  • Thermal relays in use should be checked once a week


  • The thermal relay in use should be serviced once a year




Apply


Thermal relays are used for overload protection, especially in electric motors, where they prevent tripping due to short-term overload.


Give a tip and encourage the author!
Recommended
Relay Protection Types in Substations: A Complete Guide
Relay Protection Types in Substations: A Complete Guide
(1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
Echo
11/05/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.