Why Use Vegetable Oil in High-Voltage Transformers?

Noah
Noah
Field: Design & Maintenance
Australia

Application of Vegetable Oil in High-Voltage Power Transformers

Vegetable oil transformers are more environmentally friendly, safer, and longer-lasting compared to mineral oil transformers. As a result, their use is increasing both domestically and internationally. It is estimated that the number of vegetable oil transformers worldwide has already exceeded 2 million.

Among these 2 million units, the vast majority are low-voltage distribution transformers. In China, only one vegetable oil transformer rated at 66 kV or above has been put into grid operation, while the number overseas is relatively higher. Based on discussions with foreign transformer manufacturers, it is estimated that globally, the number of in-service vegetable oil transformers operating at 66 kV and above is likely fewer than 1,000. 

In terms of voltage class, the highest-rated vegetable oil transformer currently in service is a 420 kV unit manufactured by Siemens Germany, which has been operating safely since its commissioning in 2013. Since then, some manufacturers have developed and produced 500 kV vegetable oil transformers, but there are no records of grid connection to date. Additionally, the application of vegetable oil in DC systems is gradually attracting attention, with some research results beginning to be published, although no transformer manufacturers have yet announced related transformer production.

transformer..jpg

The limited application of vegetable oil in high-voltage transformers is mainly due to the fact that high-voltage transformers present higher technical barriers and greater challenges compared to distribution transformers. This poses challenges not only for transformer manufacturers but also for end-users.

  • When applying vegetable oil in high-voltage transformers, its insulation performance under highly non-uniform electric fields must be fully considered, along with its dielectric constant. This requires transformer manufacturers to conduct completely new designs, accompanied by necessary research, development, and verification.

  • Compatibility between large transformer components and vegetable oil must be considered—not only material compatibility but also adaptation to the unique insulation properties, oxidation characteristics, and viscosity characteristics of vegetable oil.

  • Currently, operational and maintenance experience with vegetable oil power transformers is limited, and international and domestic standards are incomplete. End users also need to accumulate field application data. Close collaboration among transformer manufacturers, users, and vegetable oil producers is essential.

Of course, from an industry perspective, these technical bottlenecks are not insurmountable. The primary reason for the limited number of high-voltage vegetable oil transformers lies more in market dynamics. In many countries, high-voltage transformer replacement is infrequent, resulting in low demand. In contrast, China's vegetable oil and vegetable oil transformer industry is still in its early stages. The large-scale development of vegetable oil power transformers will take time. Zedian (a nickname for the author/editor) boldly predicts that, as time progresses and given China’s position as the world's transformer manufacturing base, China will inevitably become the leading force in the global vegetable oil power transformer market.

Give a tip and encourage the author!
Recommended
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli
Echo
11/03/2025
Standards and Calculation of LTAC Test for Power Transformers
Standards and Calculation of LTAC Test for Power Transformers
1 IntroductionAccording to the provisions of the national standard GB/T 1094.3-2017, the primary purpose of the line terminal AC withstand voltage test (LTAC) for power transformers is to evaluate the AC dielectric strength from the high-voltage winding terminals to ground. It does not serve to assess inter-turn insulation or phase-to-phase insulation.Compared with other insulation tests (such as full lightning impulse LI or switching impulse SI), the LTAC test imposes a relatively more stringen
Oliver Watts
11/03/2025
What Are the Handling Procedures After Transformer Gas (Buchholz) Protection Activation?
What Are the Handling Procedures After Transformer Gas (Buchholz) Protection Activation?
What Are the Handling Procedures After Transformer Gas (Buchholz) Protection Activation?When the transformer gas (Buchholz) protection device operates, a thorough inspection, careful analysis, and accurate judgment must be carried out immediately, followed by appropriate corrective actions.1. When the Gas Protection Alarm Signal is ActivatedUpon activation of the gas protection alarm, the transformer should be inspected immediately to determine the cause of operation. Check whether it was caused
Felix Spark
11/01/2025
Fluxgate Sensors in SST: Precision & Protection
Fluxgate Sensors in SST: Precision & Protection
What is SST?SST stands for Solid-State Transformer, also known as Power Electronic Transformer (PET). From the perspective of power transmission, a typical SST connects to a 10 kV AC grid on the primary side and outputs approximately 800 V DC on the secondary side. The power conversion process generally involves two stages: AC-to-DC and DC-to-DC (step-down). When the output is used for individual equipment or integrated into servers, an additional stage to step down from 800 V to 48 V is require