   Voltage instability is a serious phenomenon that can occur in a power system because of critical or stressed conditions. To prevent voltage collapse caused by such instability, accurate voltage collapse prediction is necessary for power system planning and operation. This paper proposes a novel collapse prediction index (NCPI) to assess the voltage stability conditions of the power system and the critical conditions of lines. The effectiveness and applicability of the proposed index are investigated on the IEEE 30-bus and IEEE 118-bus systems and compared with the well-known existing indices (L mn , FVSI, LQP, NLSI, and VSLI) under several power system operations to validate its practicability and versatility. The study also presents the sensitivity assumptions of existing indices and analyzes their impact on voltage collapse prediction. The results show the superiority of the proposed index in accurately estimating the maximum load-ability and predicting the critical lines, weak buses, and weak areas in medium and large networks during various power load operations and contingencies.

1.Introduction.

     Voltage instability is one of the significant problems in the electricity system that needs to be considered to secure power transfer to consumers. Because of a continuous increase in electrical load the present-day electrical power system urgently requires secure electrical power transmission facilities. From an environmental and economic point of view, it is challenging to install new transmission lines. Also, the situation becomes more complex with the increasing penetration of renewable energies. The most crucial challenge facing the network is excessive loading in transmission lines resulting in a massive voltage drop, which can cause voltage collapse due to overload on the lines. In this case, the line becomes in a critical state, and the system can face collapse under even small disturbances. Voltage collapse leads to the exit of a line from the system when the loading exceeds the allowable limit. Subsequently, the exiting of the line from the system increases the power flow in other lines, potentially causing consecutive exits of the lines and leading to the blackout of the entire network.

2.Voltage Stability Indices(VSIs).

     VSIs are used as measurement tools to determine whether a system is stable or not. There are many methods for voltage stability assessment that have been suggested in the literature. Three categories of VSIs are classified: line VSIs, bus VSIs, and overall VSIs. The classification of VSIs, can be grouped into four types: (1) line variables based-indices; (2) bus variables based-indices;(3)Jacobian matrix-based indices; and (4)Phasor Measurement Units (PMU)-based indices. Jacobian matrix-based indices can identify the voltage collapse points and determine the stability margin.

3.Proposed Novel Collapse Prediction Index NCPI.

     The formulation of the index LQP is based on entirely ignoring the line resistance. This leads to erroneous collapse predictions. This index also ignores the relative direction of active power flow in a line in relation to reactive power flow. In order to avoid these drawbacks, an improved Novel Collapse Prediction Index (NCPI) is formulated based on partially ignoring the resistance of a transmission line, while taking into account the impacts of the active and reactive power flow on the system voltage stability.

Single line diagram of power transmission line.png

4.Voltage stabilty Analysis Based on NCPI.

    The main goal of voltage stability analysis is to determine the voltage collapse points, maximum load-ability, weak buses and critical lines using the proposed index NCPI. Voltage stability normally has a high sensitivity to reactive power load. Therefore, the heavy reactive power at each particular bus is determined to identify the weak buses and critical lines. 

Flow chart for weak buses and critical lines identification.png

5.Contingency Ranking and Analysis Based on NCPI.

      The results show the most sensitive or critical line due to line outage or generation unit outage, which has the highest NCPI value among the lines. The most critical line is eligible to be interrupted from the service due to a line outage. In this case, a series of line outages will occur if operators don't make rectifications in time.

Flow chart for contingency ranking and analysis.png

Source: IEEE Xplore

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.


IEEE Xplore

IEEE​ (pronounced "I-triple-E") stands for the ​Institute of Electrical and Electronics Engineers, a global professional organization dedicated to advancing technological innovation for the benefit of humanity. Founded in 1963 through the merger of the American Institute of Electrical Engineers (AIEE) and the Institute of Radio Engineers (IRE), IEEE has grown into the world’s largest technical professional society, with over ​400,000 members​ across ​160+ countries.

Difference Between Shunt and Series Voltage Regulator
Difference Between Shunt and Series Voltage Regulator
Linear voltage regulators are mainly classified into two types: shunt voltage regulators and series voltage regulators. The key difference between them lies in the connection of the control element: in a shunt voltage regulator, the control element is connected in parallel with the load; in contrast, in a series voltage regulator, the control element is connected in series with the load. These two types of voltage regulator circuits operate on different principles and thus have their own advanta
Edwiin
07/25/2025
Research on the Evaluation Method of Uncertainty in the Verification and Measurement Results of Electronic Voltage Transformers in Power Grids
Research on the Evaluation Method of Uncertainty in the Verification and Measurement Results of Electronic Voltage Transformers in Power Grids
1. IntroductionGrid electronic voltage transformers, as indispensable measuring components in power systems, have their measurement accuracy directly tied to the stable operation and efficient management of power systems. However, in practice, due to the inherent characteristics of electronic components, environmental factors, and limitations of measurement methods, the measurement results of voltage transformers often involve uncertainty. This uncertainty not only impacts the accuracy of power
Oliver Watts
07/24/2025
Electromagnetic Compatibility Performance Design of Electronic Voltage Transformers
Electromagnetic Compatibility Performance Design of Electronic Voltage Transformers
1 Overview of EMC Performance of Electronic Voltage Transformers1.1 Definition & Requirements of EMCElectromagnetic Compatibility (EMC) denotes a device/system’s ability to operate undisturbed in a given electromagnetic environment and avoid causing unacceptable electromagnetic interference to other entities. For electronic voltage transformers, EMC demands stable measurement performance in complex settings, without interfering with other devices. Their EMC performance must be factored
Dyson
07/23/2025
How to avoid step voltage?
How to avoid step voltage?
Hey everyone, I'm Blue — an electrical engineer with over 20 years of experience. My work has mainly focused on circuit breaker design, transformer management, and delivering power system solutions for various utility companies.Today, someone asked a great question: "How to avoid step voltage?" Let me explain this in simple but professional terms.First off, what exactly is step voltage (or touch potential between your feet)?Imagine this: when a high-voltage line falls to the ground or there's a
Master Electrician
07/11/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!