• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


10.24kWH-20.48kWH Stacked Energy Storage System(ESS)

  • 10.24kWH-20.48kWH Stacked Energy Storage System(ESS)

Key attributes

Brand RW Energy
Model NO. 10.24kWH-20.48kWH Stacked Energy Storage System(ESS)
Rated Output Rating 5kW
Energy storage capacity 30.72kWh
Cell quality Class A
Series SESS

Product descriptions from the supplier

Description

Stacked ESS

 企业微信截图_1728974724403.png

The ESS series products (Energy Storage System) adopt high-quality lithium iron phosphate battery cells, are equipped with an intelligent BMS (Battery Management System), featuring a long cycle life, high safety performance, and good sealing. They are equipped with a high-frequency off-grid photovoltaic inverter and a built-in MPPT controller, which can provide efficient and reliable energy solutions for off-grid photovoltaic power generation systems, energy storage systems, household photovoltaic energy storage systems, and industrial and commercial energy storage systems.

This system is equipped with an independently developed APP that supports IOS/Android. It enables remote control of battery pack charging and discharging, real-time monitoring of system operation data, and can quickly enter troubleshooting work when a system operation failure occurs, thus efficiently restoring effective power supply.                     

Peculiarity

  • Custom stacking capacity, integrated installation free.

  • Battery pack is replaceable, can be adapted to a variety of batteries, for different batteries to achieve different charging and discharging strategies.

  • Energy scheduling can be regulated, users can change the charge and discharge according to the power consumption policy of different periods in the region; Low logical O&M cost.

  • Support battery pack voltage, capacity customization, to meet different use environment

  • Mature technology, long cycle life, high safety performance.

  • Modular design, high power density, easy maintenance.

Technical parameter

image.png

image.png

Note:

  • The A-class cell can charge and discharge 6000 times, and the B-class cell can charge and discharge 3000 times, and the default discharge ratio is 0.5C.

  •  Class A cell warranty 60 months, Class B cell warranty 30 months.

Application scenarios

  1. Small apartment / rental home energy storage 

    Adaptation advantages: The stacked design only occupies 0.3㎡ of floor space (about the size of a bedside table), no installation required, can be directly placed on the balcony; 10.24kWh capacity supports the continuous operation of refrigerator + lighting + router for 3-5 days, with temperature resistance of -30℃~50℃, suitable for most areas in the region, covering "small apartment stacked ESS" and "household energy storage".

  2. Backup power supply for small commercial places

    Adaptation advantages: 20.48kWh capacity can support the operation of convenience store freezers + cash registers for 6-8 hours; modular stacking supports expansion to 30.72kWh, replaceable battery packs avoid waiting for charging during power outages, covering "small commercial stacked energy storage" and "convenience store backup ESS".

  3. Outdoor temporary power supply (camping / small-scale construction)

    Adaptation advantages: A single module weighs about 25kg and can be manually carried, IP20 dustproof suitable for dry outdoor scenes; 5kW rated output can power electric drills, lighting, portable ovens, replacing fuel generators to achieve noise-free and clean power supply, covering "outdoor temporary energy storage scenarios".

Documentation Resource Library
Public.
Household Energy Storage Battery(ESS)selection catalog
Catalogue
English
FAQ
Q: How to ensure that the voltage and capacity of each battery cell are consistent in ESS?
A:

The role of the Battery Management System (BMS).

  • Real-time monitoring:The BMS monitors parameters such as voltage, current, and temperature of each battery cell in real time through sensors to ensure the health status of each cell.

  • Equalization management:The equalization circuit (Balancing Circuit) in the BMS is used to adjust the voltage differences between each battery cell. When a cell voltage is detected to be lower than the set value, the equalization circuit will perform voltage compensation in a passive or active way to make the voltages of all cells tend to be consistent.

Equalization strategies.

  • Passive balancing:Excess charge is dissipated through resistors connected in parallel to the battery cells, thereby making the voltges of each cell tend to be consistent.
    The disadvantage is that it can only work during the battery charging process and has a large energy loss.

  • Active balancing:Using a bidirectional converter or a dedicated equalization chip to transfer charge between battery cells to achieve energy transfer, thereby making the voltages of each cell consistent.
    The advantage is that it can be adjusted bidirectionally. It can equalize during charging and discharging, and has low energy loss.

Q: Can you withstand extreme weather outdoors?
A:

IP20 can only be placed in a dry room, but it has a wide temperature tolerance of -30 ℃ to 50 ℃. 25kg per module, easy to move, can be used in campsites and construction sites, replacing fuel generators, quiet and environmentally friendly.

Q: How to quickly recover from a power outage?
A:

The battery pack is replaceable! When there is a power outage, replace the battery with a new one and it takes 5 minutes to complete. The cash register and refrigerator keep running. Small convenience stores use this to avoid product damage or data loss, making emergency response extremely efficient.

Q: Can the capacity be increased?
A:

Can it! Basic 20.48kWh, stacked to 30.72kWh like building blocks. A small shop can use 20.48kWh, but if you want a bigger one, you can simply add modules without having to replace the whole machine, saving money and effort.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.